Skip to content
3/2-Way NCDN 4.0 mmVacuum -1 to 3 barBrass BodyFKM Seal120 V 60 HzMedia SeparatedIP65

BURKERT 462569 Type 0330 Direct-Acting 3/2-Way Pivoted Armature Solenoid Valve, NPT 1/4, 120 V 60 Hz

BURKERT 462569 (Type 0330) is a direct-acting 3/2-way pivoted armature solenoid valve, brass body, FKM seal, NPT 1/4, 4 mm orifice, -1 to 3 bar vacuum rating, 120V 60Hz coil, and IP65 protection.

BURKERT 462569 Type 0330 Direct-Acting 3/2-Way Pivoted Armature Solenoid Valve, NPT 1/4, 120 V 60 Hz

BURKERT 462569 (Type 0330) is a direct-acting 3/2-way pivoted armature solenoid valve configured in circuit function C (normally closed) with an integrated media-separating diaphragm. Designed for demanding gaseous and liquid media, article 462569 features a brass body, FKM seals, an orifice size of 4.0 mm (Kv 0.23 m³/h, QNn 255 l/min), and NPT 1/4 female threaded ports. The solenoid actuator is isolated from the fluid chamber by the diaphragm system, preventing media contact with the magnetic core assembly and eliminating corrosion risks. This unit operates across a pressure range of -1.00 bar to 3.00 bar, providing vacuum service, and is powered by a 120 V AC, 60 Hz epoxy coil rated for 100% ED continuous operation.

Technical Data and Operating Parameters ​

Article 462569 delivers fast cycle times and media isolation in neutral and aggressive fluids with a viscosity of up to 37 mm²/s.

Specification ParameterValue
Article Number462569
Valve Type0330
Circuit FunctionC (3/2-way, normally closed: P/NC closed, A/OUT to R/NO connected)
Orifice SizeDN 4.0 mm (5/32")
Flow CoefficientsKv (water): 0.23 m³/h; QNn (gas): 255 l/min
Pressure Range-1.00 bar to 3.00 bar (Vacuum variant NA02)
Port ConnectionNPT 1/4 female thread
Valve Body MaterialBrass (MS)
Valve Seat MaterialBrass (MS)
Sealing MaterialFKM (Fluor rubber, Shore hardness 70)
Operating Voltage120 V AC (60 Hz), tolerance ±10%
Coil Power ConsumptionInrush: 30 VA, Hold: 15 VA / 8 W
Coil Insulation ClassClass H (Epoxy encapsulation)
Duty Cycle100% continuous operation (100% ED)
Switching TimesOpening: 8 to 15 ms, Closing: 8 to 15 ms (at 20 °C, 6 bar)
Medium Temperature Range0 °C to +90 °C
Permissible Ambient TemperatureMax. +55 °C (Storage: -40 °C to +80 °C)
Electrical Protection DegreeIP65 according to DIN EN 60529 / IEC 60529 (with cable plug)

Media Separation and Material Construction ​

Type 0330 isolates the coil mechanism from process media using a flexible separating diaphragm. The fluid chamber and body materials resist chemical breakdown when handling oxidizing acids, hot oils with additives, salt solutions, and waste gases compatible with brass and FKM.

BURKERT 462569 Type 0330 sectional view and component materials

Item NumberComponentMaterial
1Solenoid CoilEpoxy encapsulation
2DiaphragmFKM (Fluor rubber)
3O-RingFKM (Fluor rubber)
4Valve SeatBrass
5Valve BodyBrass

Media Compatibility Verification

Verify specific chemical combinations using the Bürkert resistApp tool prior to handling unlisted corrosive compounds. For media with particulates, install upstream filtration to protect the sealing surface.

Circuit Function and Fluidic Port Assignment ​

Circuit function C operates as a 3/2-way normally closed valve. In the de-energized rest state, pressure port 1 (P) is shut off, while working port 2 (A) vents to exhaust port 3 (R). When energized, the pivoted armature shifts, connecting port 1 (P) directly to port 2 (A), while shutting off exhaust port 3 (R).

BURKERT 462569 Type 0330 3-way fluidic port connection assignment

Circuit FunctionConnection Port 1Connection Port 2Connection Port 3
A (2/2-way NC)PA—
B (2/2-way NO)BP—
C (3/2-way NC, 462569 standard)PAR
D (3/2-way NO)RBP
E (3/2-way Mixing)P1AP2
F (3/2-way Distribution)APB
T (3/2-way Universal)NCIN / OUTNO
Operation in Alternative Circuit Functions

The internal compression springs in Type 0330 valves are factory-matched to the specified circuit function. If a function C valve is connected in alternative circuit arrangements, the permissible operating pressure changes according to the following ratings for a DN 4 metal body valve:

Original Valve FunctionTarget Circuit Function ATarget Circuit Function BTarget Circuit Function CTarget Circuit Function DTarget Circuit Function ETarget Circuit Function F
Function C (DN 4 Metal)5.0 bar0.8 bar5.0 bar0.8 bar0.8 bar5.0 bar

Dimensions and Mechanical Installation ​

Article 462569 features an overall installation body length of 46 mm and female NPT 1/4 threaded ports on a brass valve housing. Bottom mounting holes follow a standardized 38 mm x 24 mm pattern for secure mechanical support.

BURKERT 462569 Type 0330 metal body threaded connection dimensions

Thread Designation D1Thread Length L1Thread Designation D2Thread Length L2
G 1/89.0 mm——
G 1/49.0 mmNPT 1/47.5 mm

Upstream Filtration Requirement

For safe operation of the solenoid valve, a dirt trap with mesh size ≤ 500 µm must be installed upstream of the valve inlet. Check pipelines for debris and flush before connecting.

  • Installation Position: Flexible mounting orientation; actuator upright is preferred.
  • Fastening: Secure the valve using M4 x 8 tapped holes located on the underside of the housing (38 mm x 24 mm hole pattern).
  • Thread Engagement: For NPT 1/4 threads, ensure adequate engagement while respecting the 7.5 mm minimum thread depth on middle ports.
  • Piping Tooling: Hold the valve by the brass body flats using an open-ended spanner. Do not use the solenoid coil as a lever arm.

Manual Override and Electrical Connection ​

Type 0330 incorporates a lockable manual override on the actuator housing to assist commissioning, testing, and manual override cycles.

BURKERT 462569 Type 0330 manual override operating mechanism

Manual Override Interlock

When the manual override is rotated clockwise into the locked position, the valve cannot be electrically actuated. Always return the override to its neutral position before resuming electrical control.

Electrical Wiring ​

Electrical connection is established via plug contacts matching Form A according to DIN EN 175301-803 (DIN 43650 Design A), suitable for cable plug Type 2518 or Type 2509.

  • Connect power leads to terminals 1 and 2 independently of polarity.
  • Connect the protective ground conductor (PE) to the ground terminal and verify electrical continuity between coil housing and valve body.
  • Tighten the cable plug central mounting screw with a maximum tightening torque of 1.0 Nm.

BURKERT 462569 Type 0330 type label element identification

PositionDescriptionPositionDescription
1Valve Type (0330)7Nominal Pressure (PN)
2Circuit Function (C)8Active Coil Power (8 W)
3Orifice (4.0 mm)9Manufacturing Code
4Sealing Material (FKM)10Article Number (462569)
5Body Material (Brass MS)11Supply Voltage (120 V / 60 Hz)
6Connection Type (NPT 1/4)

Maintenance and Troubleshooting ​

De-energize and Depressurize

Before performing maintenance or disassembling the valve from the piping system, turn off the line pressure, drain and deaerate all lines, and switch off electrical power to prevent accidental energization.

Fault ConditionProbable CauseCorrective Action
Valve does not actuateSolenoid coil interrupted or short circuitCheck electrical wiring, supply voltage, and coil resistance.
Operating pressure out of specificationVerify supply pressure is within -1.0 to 3.0 bar range.
Manual override locked in actuated positionUnlock manual override by turning counter-clockwise.
Valve does not closeValve interior contaminated with particulatesDisassemble valve body and clean internal seats and diaphragm.
Manual override lockedReturn manual override to unlocked neutral position.
Media leakage at body jointFastening screws loose or seal deterioratedInspect FKM diaphragm and O-ring; retighten body screws evenly.