Skip to content
Direct-actingMedia-separatedIP65

BURKERT 48988 3/2-Way Direct-Acting Solenoid Valve, G 1/4, 0-10 bar, Stainless Steel

Burkert 48988 (Type 0330) 3/2-way direct-acting solenoid valve. Normally closed (Circuit Function C), stainless steel body, FKM seal, 48V DC, 0-10 bar.

BURKERT 48988 3/2-Way Direct-Acting Solenoid Valve, G 1/4, 0-10 bar, Stainless Steel

Burkert 48988 (Type 0330) is a direct-acting, media-separated pivoted armature solenoid valve. Configured with a 3/2-way normally closed circuit function (C), this specific model features a 3.0 mm orifice, a stainless steel body, and FKM seals, making it highly suitable for critical and aggressive media. The solenoid coil is moulded with a chemically resistant epoxy, and the internal coil system is completely separated from the medium by a diaphragm. It operates on 48 V DC and handles pressures from 0 to 10 bar.

INFO

This page details the specific configuration for article number 48988. The Type 0330 family includes various other materials and circuit functions not covered in this specific SKU profile.

Technical Data

PropertyValue
OrificeDN 3.0 mm
Circuit FunctionC (3/2-way, normally closed)
Pressure Range0 to 10 bar
Voltage48 V DC
Kv Value (Water)0.14 m³/h
QNn Value (Gas)150 l/min
Medium Temperature0 °C to +90 °C
Ambient TemperatureMax. +55 °C
Duty Cycle100% continuous operation
Degree of ProtectionIP65 with cable plug

Circuit Function

Circuit Function C (CF C) 3/2-way solenoid valve, direct-acting, normally closed.

Burkert 48988 circuit function C normally closed diagram

Material Specifications

ElementMaterial
CoilEpoxy
Diaphragm / O-ringFKM (Fluor rubber)
SeatStainless steel (1.4401)
Valve BodyStainless steel (1.4401)

Dimensions

Metal Body (Stainless Steel)

  • Port Connection: G 1/4
  • D1: G 1/4
  • L1: 9 mm

Burkert 48988 metal body dimensions drawing

Installation Notes

  • The installation position is flexible, but preferably with the actuator upright.
  • For safe operation, a dirt trap (≤ 500 µm) must be installed before the valve inlet.
  • The device can be attached via the existing holes on the bottom side (hole pattern 38x24) using M4 screws for metal bodies.

Safety Instructions

DANGER

Risk of injury from high pressure in the system/device ▶ Before working on equipment or device, switch off the pressure and deaerate/drain lines.

Risk of injury from electric shock ▶ Before working on the system or device, switch off the power supply and secure against reactivation. ▶ Observe the applicable accident prevention and safety regulations for electrical devices.

WARNING

Risk of burns or fire from hot device surfaces due to prolonged activation time ▶ Keep the device away from highly flammable substances and media and do not touch with bare hands.