Direct-actingUp to DN 2.5Vibration-proofExplosion-proof variants

BURKERT 501212 Type 6014 3/2-Way Direct-Acting Plunger Valve

Bürkert Type 6014 is a direct-acting, compact 3/2-way plunger solenoid valve with a diameter up to DN 2.5. Features a vibration-proof bolted coil system and explosion-proof variants.

BURKERT 501212 Type 6014 3/2-Way Direct-Acting Plunger Valve

Bürkert Type 6014 is a direct-acting plunger valve designed for reliable fluid control. The stopper and core guide tube are welded together to enhance pressure resistance and leak-tightness. Various seal material combinations are available depending on the application. A Bürkert-specific flange variant (SFB) enables space-saving arrangement of valves on a manifold. Kick and Drop coils are available for the reduction of electrical power consumption during operation.

BURKERT 501212 Bürkert Type 6014 3/2-way direct-acting plunger valve

General Technical Data

Product properties
OrificeDN 1.5...DN 2.5
Circuit functionC, D and T
Thermal insulation classPolyamide coil class B, Epoxy coil class H
Duty cycle100% continuous operation. Intermittent operation 60% (30 min) or with 5 W coil (on request)
Operating voltage24 V DC, 24 V 50 Hz, 24 V 60 Hz, 110 V 50 Hz, 120 V 60 Hz, 230 V 50 Hz, 240 V 60 Hz
Voltage tolerance±10%
Operating mediumTechnical vacuum, neutral gases and liquids (e.g. compressed air, town gas, natural gas, water, hydraulic oil, petrol)
Medium temperature (FKM)-10 °C...+100 °C (PA coil), -10 °C...+120 °C (epoxy coil), -40 °C on request
ViscosityMax. 21 mm²/s
Port connectionG 1/8, G 1/4, NPT 1/8, NPT 1/4, sub-base (SFB)
Degree of protectionIP65 with cable plug Type 2518, NEMA 4X with cable plug Type 2509 with stainless steel variants
Installation positionAs required, preferably with actuator upright
Ambient temperatureMax. +55 °C

Circuit Functions

SymbolDescription
BURKERT 501212 Bürkert Type 6014 Circuit function C normally closedCircuit function C (CF C)
3/2-way solenoid valve
Direct-acting
Normally closed
BURKERT 501212 Bürkert Type 6014 Circuit function D normally openCircuit function D (CF D)
3/2-way solenoid valve
Direct-acting
Normally open
BURKERT 501212 Bürkert Type 6014 Circuit function T flow direction optionalCircuit function T (CF T)
3/2-way solenoid valve
Direct-acting
Flow direction optional
Normally closed

Material Specifications

BURKERT 501212 Bürkert Type 6014 standard variant material specifications

No.ElementMaterial
1StopperStainless steel 1.4105/430F
2Shading ringCu (brass variant), Ag (stainless steel variant)
3Plunger sealFKM
4SpringStainless steel 1.4310/301
5Magnetic coreStainless steel 1.4105/430F
6Core guide tubeStainless steel 1.4303/305/308
7O-ringFKM
8Plunger sealFKM
9Valve bodyBrass, Stainless steel 1.4305/303, Stainless steel 1.4401/316
10SpringStainless steel 1.4310/301
11Sub-baseSteel, surface finish thick-film passivated (brass variant), Stainless steel 1.4301/304 (stainless steel variant)
12CoilPA (Polyamide), Epoxy (High temperature variant)
13NutSteel, surface finish thick-film passivated (brass variant), Stainless steel 1.4305/303 PTFE coated (stainless steel variant)

Dimensions

Note

Dimensions are in mm.

BURKERT 501212 Bürkert Type 6014 standard variant dimensions

Port connectionA [inch]B [mm]C [mm]D [mm]G [mm]
Threaded without manual overrideG 1/83220.832.68
Threaded without manual overrideG 1/44626.84912
Threaded with manual overrideG 1/83220.832.68
Threaded with manual overrideG 1/44626.84912
Sub-base-3214.332.6-

Performance Specifications

Power Consumption

Orifice [mm]Coil power [W]Power consumption Inrush AC [VA]Power consumption Hold AC [VA/W]Response times Opening [ms]Response times Closing [ms]
1.58 W AC or 8 W DC (9)24810...1515...20
2.08 W AC or 8 W DC (9)24810...1515...20
2.58 W AC or 8 W DC (9)24815...2010...22

(Measurement at +20 °C, 6 bar at the valve outlet, opening: pressure build-up 0…90%, closing: pressure reduction 100…10%)

Utilisation in Another Circuit Function

The valves are equipped with different springs for specific circuit functions. When used with other circuit functions, the permissible operating pressure changes according to the following table.

DNCircuit functionMax. operating pressure [bar] AMax. operating pressure [bar] BMax. operating pressure [bar] CMax. operating pressure [bar] DMax. operating pressure [bar] T
1.5C16221622
1.5D22.52162
1.5T10161066
2.0C10141011
2.0D11.51101
2.0T610644
2.5C6960.70.7
2.5D0.710.760.7
2.5T3.563.52.52.5

Explosion Protection

Optional explosion protection according to category 2 (zone 1/21) and category 3 (zone 2/22) is available. The maximum medium temperature must never exceed the permitted temperature class (T4: +135 °C, T5: +100 °C, T6: +85 °C) minus 5 K.