3/2-WayDirect-ActingStainless SteelEPDM SealIP65

BURKERT 51499 Type 0331 3/2-Way Direct-Acting Solenoid Valve, Flange, Stainless Steel

Burkert Type 0331 (SKU 51499) 3/2-way direct-acting solenoid valve. Features stainless steel body, flange connection, EPDM seal, 2.0mm orifice, 0-16 bar pressure range, and 110V AC operation.

BURKERT 51499 Type 0331 3/2-Way Direct-Acting Solenoid Valve, Flange, Stainless Steel

BURKERT 51499 Type 0331 is a direct-acting, media-separated pivoted armature 3/2-way solenoid valve. The solenoid actuator and the medium chamber are separated from each other by a separating membrane system. The valves are fast-acting and have a long service life. This specific model features a stainless steel body, flange connection, EPDM seal, and operates at 110V AC.

System Description ​

The Type 0331 valve is a direct-acting, media-separated pivoted armature valve. As a 3/2-way variant, it can be used as a distributor or mixing valve. The solenoid coils are moulded with a chemically resistant epoxy. Since the coil system is separated from the medium by a diaphragm, the valve is especially suitable for critical media such as aggressive acids and lyes. The 0331 is equipped with a manual override for start-up and testing.

Technical Data ​

  • Circuit Function: D (normally open - inlet port 1 (P/NO) connected with outlet port 2 (B/OUT), exhaust port 3 (R/NC) closed)
  • Orifice: 2.0 mm
  • Pressure Range: 0 to 16 bar
  • Medium Temperature (EPDM): -30 °C to +90 °C
  • Ambient Temperature: Max. +55 °C
  • Body Material: Stainless steel
  • Seal Material: EPDM
  • Port Connection: Bürkert flange 32 x 46 version A2
  • Voltage: 110 V (50/60 Hz)
  • Degree of Protection: IP65 with cable plug

BURKERT 51499 Circuit function D

Materials ​

No.ElementMaterial
1CoilEpoxy
2DiaphragmEPDM
3O-ringEPDM
4SeatStainless steel (1.4401)
5Valve bodyStainless steel (1.4401)

Installation and Operation ​

Installation Safety

Risk of injury from high pressure in the system/device. Before working on equipment or device, switch off the pressure and deaerate/drain lines.

Installation position: As required, preferably with actuator upright. Dirt trap: For safe operation of the solenoid valve, a dirt trap (≤ 500 µm) must be installed before the valve inlet.

Manual Override ​

When manual override is locked, the valve cannot be electrically actuated. BURKERT 51499 Manual override

  1. Press and hold the manual override.
  2. Turn manual override clockwise.

Electrical Connection ​

BURKERT 51499 Electrical connection

  1. Cable plug
  2. Seal

Install an approved cable plug, e.g. Type 2518 or other suitable cable plug in accordance with DIN EN 175301-803 Design A. Observe voltage and current type in accordance with type label.

BURKERT 51499 Type label