WirelessHART 2.4 GHz
TLV iT5-IS-TPN TrapSensor is an intrinsically safe wireless monitoring sensor for simultaneous temperature and pressure measurement up to 400 °C, based on ISA 100.11a.

The TLV iT5-IS-TPN TrapSensor is a wireless monitoring sensor designed for high-frequency monitoring of crucial steam-using equipment such as heat exchangers, pumps, turbines, and equipment with the possibility of air present in steam piping. It provides simultaneous temperature and pressure measurement based on the ISA 100.11A communication protocol.

| Model | iT5-IS-TPN |
|---|---|
| Maximum Measurement Temperature (°C) | 400 |
| Measurable Temperature Range (°C) | -40 to +400 |
| Measurable Temperature Accuracy (°C) | ±1 |
| Minimum Ambient Temperature (°C) | -40 |
| Maximum Ambient Temperature (°C) | -40 to < 125: 80 125 to < 200: 75 200 to < 300: 68 300 to < 400: 64 |
| Measurable Pressure Range | 0 to 2 MPaG, 0 to 5 MPaG |
| Measurable Pressure Accuracy | ±0.5% of full-scale |
| Maximum Allowable Pressure | Rated pressure × 2 |
| Applicable Fluids | Steam, water, air, nitrogen |
| Wireless Frequency Band | 2.4 GHz |
| Maximum No. of Connections | 500 devices per gateway |
| Maximum No. of Hops | 4 (from access point to sensor) |
| Measurement Cycle | 1 second to 1 hour |
| Power Source | Non-rechargeable lithium-thionyl chloride battery pack (Rated Voltage: 3.6 V, Rated Capacity: 38 Ah) |
| Battery Life | 10 years for regular operation (60 s measurement cycle) |
| Intrinsic Safety Specifications | ATEX: II 1G Ex ia op is IIC T4 Ga UL/cUL: Class I, Division 1, Groups ABCD IECEx: Ex ia op is IIC T4 Ga, Class I, Zone 0, AEx ia op is IIC T4, Ex ia op is IIC T4 UKEX: Ex ia op is IIC T4 Ga |
| Connection Type | Compression Fitting: Screwed Rc(PT) 15 mm Thermowell: Flanged 25 mm |
| Communication Protocol | ISA 100.11a, based on IEEE 802.15.4 |
| Regulatory Compliance | FCC, IC, CE compliant |
| Frequency Bandwidth | 2.405 to 2.480 GHz |
| Transmitter Power Output | 7.0 mW/MHz |
| Communication Distance | Approx. 400 m (with a clear line of sight) |
| Protection Class | IP66 and IP67 (evaluation for intrinsic safety is performed at IP20) |
| Body, Cover Material | Aluminium Alloy Die Castings (ADC3, SG100A) |
| Sensor Tip Material | Stainless Steel (SUS304) |
| Thermowell Material | Stainless Steel (A182 F316) |
| Options | Extended antenna type: Sensor with 150 mm antenna and 3 m or 13 m cable (intrinsically safe) |
Notes on Specifications

| Size (mm) | Weight (kg) |
|---|---|
| 15 | 2.0 |
Rc(PT), other standards available.
| Size (mm) | Connect to ASME Class | Weight (kg) |
|---|---|---|
| 25 | 300RF, 600RF | 6.0 [6.2] |
Other standards available. Contact TLV for details. [ ] 600RF
Antenna Extension


| No. | Model | Function |
|---|---|---|
| ① | Sensor: iT5-IS-TPN | Measurement of temperature and pressure, wireless transmission of information |
| ② | Repeater: iT5-IS-RUN | Wireless relay of information |
| ③ | Access Point/Gateway | Relay of information via intranet |
| ④ | Data Collection Server | Importing collected data |