Skip to content
Stainless SteelFull BoreAnti-StaticPTFE Seat

Yoshitake BLV-2SF Stainless Steel Ball Valve

Yoshitake BLV-2SF stainless steel full bore ball valve. Applicable for steam, air, water, and oil. Features anti-static design and blowout-proof stem.

Yoshitake BLV-2SF Stainless Steel Ball Valve

Yoshitake BLV-2SF is a full bore type ball valve made of stainless steel. It is designed for various non-dangerous fluids including steam, air, cold and hot water, and oil. The valve incorporates an anti-static design that prevents static electricity charging on the valve and a collar on the lower end of the stem that prevents it from popping out due to internal pressure.

Features

  1. Body of BLV–2SF is made of stainless steel.
  2. Full bore type ball valve.
  3. Anti-static design prevents static electricity charging on the valve.
  4. The collar on the lower end of the stem prevents the stem from popping out due to the internal pressure even if the gland is removed.

Yoshitake BLV-2SF features and structure

WARNING

Please confirm that the indications on the product correspond with the specifications of the ordered product model before use. If they are different, please contact us without using the product.

Specifications

ModelBLV-2SF
Nominal size15 - 100A
Application fluidSteam, air, water, oil and other non-dangerous fluids
ConnectionJIS 10K RF flanged
ASME Class 150 flanged
EN PN16 flanged
Maximum pressure / temperatureAccording to the pressure-temperature rating
Valve materialStainless steel
Seat materialPTFE

Pressure and Temperature Rating

Yoshitake BLV-2SF pressure and temperature rating table

(According to manual, max using pressure is 1.4 MPa / 1.6 MPa / 1.9 MPa depending on connection; max using temperature is 167 °C)

Yoshitake BLV-2SF pressure temperature curve

Dimensions and Weight

Nominal sizeL (JIS 10K, ANSI 150lb)L (EN PN16)HKWeight (JIS 10K)Weight (ANSI 150lb)Weight (EN PN16)
15A108130731451.91.62.1
20A117150791452.31.92.8
25A127160911653.82.84.3
32A140180.3941654.83.75.8
40A1652001132306.55.97.5
50A1782301222308.68.510.2
65A19029014423012.712.615
80A20331015132017.818.120.7
100A2293501653202428.228.5

Yoshitake BLV-2SF dimensions

Structure and Materials

Yoshitake BLV-2SF structure cross section

No.Name of PartsMaterialQ.TY
1BodyCast Stainless Steel1
2CapCast Stainless Steel1
3BallCast Stainless Steel1
4SeatPTFE2
5GasketPTFE1
6StemStainless Steel1
7Thrust WasherPTFE1
8Gland PackingPTFE3
9Stem PackingPTFE1
10GlandCast Stainless Steel1
11NutStainless Steel1set
12Stud BoltStainless Steel1set
13BoltStainless Steel2
14Spring WasherStainless Steel2
15Unti Static DeviceStainless Steel2
16StopperStainless Steel1
17Snap RingStainless Steel2
18HandleCast Stainless Steel1

Storage and Installation

Storage and Installation

(1) Store the product indoors in a dust free, low humidity, dry and ventilated environment. (2) Installation should be conducted by suitably trained personnel, wearing protective head, eye, hand and foot protection. (3) Connect the product firmly so that the fluid will not leak. (4) In order to avoid excessive piping stress in the valve, carefully align the center of the valve and the connected pipe so that they will be in line. (5) In case that the product is expected to be frozen, be sure to conduct freezing prevention measures or water draining treatment (after use). (6) The valve can be installed in both horizontal and vertical pipes, but the position must be from upright to sideways. Do not install the valve upside down.

Operation

(1) Before applying fluid, make sure that there is no danger if the fluid flow into the end of the piping. (2) When using with a high temperature fluid, do not touch the product with your bare hands. When disassembling and inspecting the product, ensure that pressure in the valve and pipe is released to atmospheric pressure. If using with high temperature fluids, cool the product down well until it can be touched with bare hands.

INFO

(1) When applying the fluid into the valve, operate the valve slowly to prevent water hammer and condensate problem. (2) The product should be used fully open or fully close.

Troubleshooting

TroubleCauseRemedy
External leak1. Nut is loose.
2. Bolt is loose.
3. Gasket is damaged.
4. Gland packing is damaged.
1. Tighten nut.
2. Tighten bolt.
3. Replace the product.
4. Replace the product.
Seat leak1. Seat is damaged.
2. Ball is damaged.
3. Foreign substances are stuck.
1. Replace the product.
2. Replace the product.
3. Remove the foreign substances.
Abnormally high operation torque1. Bolt is overtightened.
2. Foreign substances are stuck.
1. Loosen bolt and re-tighten so that there is no leak (but not too tightly).
2. Remove the foreign substances.
Abnormal sound1. Bolt is loose.1. Tighten bolt.