Skip to content
Normally OpenedStainless SteelDiaphragm TypeAC Coil

Yoshitake DP-18C Normally Opened Diaphragm Type Solenoid Valve

Yoshitake DP-18C is a high-performance normally opened diaphragm-type solenoid valve featuring a stainless steel body, AC coil, and JIS 10K FF flanged connection for air, water, and oil.

Yoshitake DP-18C Normally Opened Diaphragm Type Solenoid Valve

Yoshitake DP-18C is a high-performance, normally opened diaphragm-type solenoid valve featuring a stainless steel body and flanged connections. It is designed for reliable control of applications involving air, cold and hot water, and oil. The valve utilizes an AC coil and ensures zero valve seat leakage.

Features

  • Outstanding corrosion resistance ensured by stainless steel wetted parts.
  • Horizontal and vertical installation.

Yoshitake DP-18C solenoid valve exterior

Yoshitake DP-18C normally opened coil type

Specifications

SpecificationValue
ApplicationAir, Cold and hot water, Oil (20 cSt or less)
Working pressure0-1.0 MPa (unusable under vacuum)
Min. differential pressure0 MPa (0.1 MPa or more is required for vertical installation)
Valve seat leakageNo (by confirming pressure gauge visually)
Max. temperature60°C
OperationNormally opened
Material (Body)Stainless steel
Material (Valve)NBR (diaphragm)
ConnectionJIS 10K FF flanged

INFO

  • Available with FKM.
  • Available with a terminal box (made of resin).

Coil Specifications

SpecificationValue
Rated voltageAC100/200V or AC110/220V (50/60 Hz common)
Voltage fluctuation toleranceRated voltage ±10%
Rated current0.42/0.21A (100/200V), 0.38/0.19A (110/220V)
Starting current1.64/0.82A (100/200V), 1.48/0.74A (110/220V)
Insulation typeClass H
Protection structureDust-proof, Splash-proof
Degree of protectionIP64
Insulation resistanceMore than 50MΩ / 500V megger
Anti-voltage test1500V/min

Dimensions and Weights

The following dimensions apply to the DP-18C (normally opened, flanged type).

Nominal sizeL (mm)H (mm)H1 (mm)Weight (kg)
15A12020547.52.9
20A13021250.03.5
25A14522862.55.0
32A16025567.56.8
40A17026170.07.5
50A19527677.510.2

::: note DP-18 series uses a welding flanged structure. :::

Nominal Size Selection

For AirYoshitake DP-18C nominal size selection chart for air When selecting the nominal size of a solenoid valve whose inlet pressure (P1), outlet pressure (P2), and air (20°C) flow rate (Q) are 0.5 MPa, 0.35 MPa, and 600 m³/h (standard condition), respectively, first find intersection point (a) of P1 = 0.5 MPa and P2 = 0.35 MPa. Trace down vertically from this intersection point (a) to find intersection point (b) with Q = 600 m³/h (standard condition). Since this intersection point (b) lies between nominal sizes 20A and 25A, select the larger one, 25A.

For WaterYoshitake DP-18C nominal size selection chart for water When selecting the nominal size of a solenoid valve whose inlet pressure (P1), outlet pressure (P2), and flow rate (V) are 0.7 MPa, 0.5 MPa, and 300 L/min, respectively, first find intersection point (a) of the differential pressure across the valve [ΔP = 0.7 - 0.5 = 0.2 MPa] and V = 300 L/min. Since this intersection point (a) lies between nominal sizes 25A and 32A, select the larger one, 32A.

Structural Drawing

Yoshitake DP-18C structural drawing