Skip to content
3/2-WayDirect-ActingMedia-Separated24V DC

BURKERT 20063458 Type 0127 3/2-Way Rocker Solenoid Valve

Burkert 20063458 Type 0127 is a 3/2-way direct-acting rocker solenoid valve featuring a 1.6mm orifice, PEEK body, FFKM seal, and 24V DC operation for aggressive media.

BURKERT 20063458 Type 0127 3/2-Way Rocker Solenoid Valve

Burkert 20063458 Type 0127 is a direct-acting 3/2-way rocker solenoid valve designed with a separating diaphragm for media separation. It features a 1.6 mm orifice, a PEEK (Polyetheretherketone) body, and an FFKM (Perfluoroelastomer) seat seal, making it suitable for handling aggressive liquids and gases in laboratory, medical, and analytical technology applications. The valve operates on a 24 V DC power supply and supports a pressure range of -1 to 2 bar.

Burkert 20063458 Type 0127 rocker solenoid valve

Technical Data ​

ParameterValue
Circuit FunctionT (3/2-way, direct-acting, universal use)
Orifice Size1.6 mm
Pressure Range-1 to 2 bar
Kv Value (Water)0.05 m³/h
QNn Value (Gas)54 l/min
Switching Time25 ms (open/close)
Operating Voltage24 V DC (±10% tolerance)
Nominal Power3.0 W
Duty Cycle100% continuous operation
Ambient Temperature10 °C to 55 °C
Medium Temperature10 °C to 50 °C
Degree of ProtectionIP65 (with strands)

Installation ​

Fluidic Installation ​

High Pressure Hazard

Before loosening lines and valves, turn off the pressure and vent the lines to prevent acute risk of injury.

Dirt Trap

If necessary, install a dirt trap with a 5 μm mesh size to protect against malfunctions.

The valve can be installed in any position, preferably with the actuator facing up. Observe the flow direction and the marking of valve connections on the body:

MarkingDescription
NCNormally closed port for CFA
IN/OUTPressure port (distributor) or working port (mixer), at CFT
NONormally open port for CFB

Burkert 20063458 marking of valve connections

Flange Connection Instructions:

  1. Remove the orange cover plate. Do not remove the flange plate.
  2. Ensure that the provided seals are properly seated inside the valve.
  3. Ensure that the manifold is flat and has adequate surface quality.

Burkert 20063458 seal placement in the valve

Tightening Torque

Excessive tightening torque can damage the device. The maximum tightening torque is 0.3 ± 0.05 Nm (does not apply to self-tapping screws).

Burkert 20063458 dimension drawing for manifold

Burkert 20063458 arrangement of holes

Electrical Installation ​

Electrical Voltage

Before starting work, switch off the power supply and secure it against being switched back on.

The 20063458 model features a 500 mm wire strand electrical connection.

Burkert 20063458 two single strands electrical connection