BURKERT Type 2032 pneumatically operated T-diaphragm valve with PPS actuator. Features stainless steel body, EPDM diaphragm, and weld end connections for hygienic applications up to 10 bar.

BURKERT Type 2032 externally controlled diaphragm valve consists of a pneumatically operated piston actuator, a diaphragm, and a T-valve body. The proven and robust actuator with a plastic housing ensures use in hygienic or aggressive ambient conditions. The flow-efficient valve bodies with little dead space enable high flow rates and a wide range of possible uses. The valve body and the diaphragm are available in all common materials and variants. The actuator has a compact, autoclavable design (PPS variant). The integration of automation units is possible in all configuration levels. An explosion-proof ATEX/IECEx device variant is available.

| Product properties | |
|---|---|
| Block body (VH) | Stainless steel block material 1.4435 according to DIN EN 10088 and 316L according to ASTM A479 / A479M |
| Block body (VI) | Stainless steel block material 1.4435 according to DIN EN 10088 and 316L according to ASME BPE |
| Diaphragm | EPDM (AD), PTFE/EPDM (EA), Advanced PTFE/EPDM (EU), laminate of GYLON® and EPDM (ER) |
| Actuator | PPS, PA |
| Diaphragm size | 8...100 |
| Standard surface quality | Internally electrically polished: Ra ≤ 0.38 μm (ASME BPE SF4 / DIN HE4) Internally mechanically polished: Ra ≤ 0.5 μm (ASME BPE SF1) |
| Performance data | |
|---|---|
| Maximum pilot pressure (CF A) | 7 bar (for actuator size 40 to 125 / PPS) 6 bar (for actuator size 175 and 225 / PA) |
| Pilot air port | Thread G 1/4, thread G 1/8 for actuator size 40 and 50 |
| Medium data | |
|---|---|
| Operating medium | Neutral gases and liquids, highly purified, sterile, aggressive or abrasive mediums |
| EPDM (AD) | -10 °C...+143 °C (steam sterilisation max. +150 °C for 60 min) |
| PTFE/EPDM (EA) | -10 °C...+130 °C (steam sterilisation max. +140 °C for 60 min) |
| Advanced PTFE/EPDM (EU) | -5 °C...+143 °C (steam sterilisation max. +150 °C for 60 min) |
| Laminate of GYLON® and EPDM (ER) | -5 °C...+130 °C (steam sterilisation max. +140 °C for 60 min) |
| Control medium | Neutral gases, air |
| Environment and installation | |
|---|---|
| PPS, actuator size ≤ 80 mm | +5 °C...+140 °C |
| PPS, actuator size 100 mm, 125 mm | +5 °C...+90 °C (short-term up to +140 °C) |
| PA, actuator size ≤ 125 mm | -10 °C...+60 °C |
| PA, actuator size ≥ 175 mm | -10 °C...+50 °C |

| No. | Element | Material |
|---|---|---|
| 1 | Transparent cap | Polysulfone PSU |
| 2 | Cover | Polyphenylene sulphide PPS (standard) / Polyamide PA (on request) |
| 3 | Pilot air ports | Stainless steel 1.4305 |
| 4 | Piston seal | FKM |
| 5 | Socket | Sinter metal |
| 6 | Interface | Stainless steel 1.4404 |
| 7 | Diaphragm | EPDM (AD), PTFE/EPDM (EA), Advanced PTFE/EPDM (EU), laminate of GYLON® and EPDM (ER) |

| No. | Element | Material |
|---|---|---|
| 1 | Cover | Polyamide PA |
| 2 | Pilot air ports | Stainless steel 1.4305 |
| 3 | Diaphragm bonnet | Stainless steel 1.4308 |
| 4 | Diaphragm | EPDM (AD), PTFE/EPDM (EA), Advanced PTFE/EPDM (EU), laminate of GYLON® and EPDM (ER) |
INFO
Dimensions in mm, unless otherwise stated.
Diaphragm size 8…50

Diaphragm size 65…100

| Diaphragm size | Actuator size ∅ | ∅ A | C | K | H |
|---|---|---|---|---|---|
| 8 | 40 (C) | 53 | 34 | G 1/8" | 111 |
| 15 | 50 (D) | 64 | 39 | G 1/8" | 137 |
| 15 | 63 (E) | 80 | 52 | G 1/4" | 154 |
| 20 | 63 (E) | 80 | 52 | G 1/4" | 165 |
| 20 | 80 (F) | 101 | 52 | G 1/4" | 186 |
| 25 | 63 (E) | 80 | 52 | G 1/4" | 170 |
| 25 | 80 (F) | 101 | 60 | G 1/4" | 190 |
| 40 | 100 (G) | 127 | 73 | G 1/4" | 246 |
| 40 | 125 (H) | 158 | 86 | G 1/4" | 284 |
| 50 | 100 (G) | 127 | 73 | G 1/4" | 254 |
| 50 | 125 (H) | 158 | 86 | G 1/4" | 288 |
| 65 | 175 (K) | 211 | 130 | G 1/4" | 350 |
| 80 | 175 (K) | 211 | 130 | G 1/4" | 350 |
| 80 | 225 (L) | 261 | 155 | G 1/4" | 345 |
| 100 | 225 (L) | 261 | 155 | G 1/4" | 345 |

TIP
The clamp dimensions must be added to the welded connection dimensions.

| Diaphragm size | Actuator size ∅ | Pilot pressure [bar] | Max operating pressure EPDM, FKM [bar] | Max operating pressure PTFE, GYLON® [bar] |
|---|---|---|---|---|
| 8 | 40 (C) | 5.0...7 | 10 | 10 |
| 15 | 50 (D) | 5.0...7 | 10 | - |
| 15 | 63 (E) | 5.0...7 | 10 | 10 |
| 20 | 63 (E) | 5.5...7 | 10 | 10 |
| 20 | 80 (F) | 5.0...7 | 10 | 10 |
| 25 | 80 (F) | 5.5...7 | 10 | 10 |
| 40 | 100 (G) | 5.5...7 | 10 | 9 |
| 40 | 125 (H) | 5.5...7 | 10 | 10 |
| 50 | 125 (H) | 5.5...7 | 10 | 10 |
| 65 | 175 (K) | 5.0...6 | 10 | 6 |
| 80 | 175 (K) | 5.0...6 | 7 | 4 |
| 80 | 225 (L) | 5.0...6 | 10 | 10 |
| 100 | 225 (L) | 5.0...6 | 10 | 7 |
WARNING
For low operating pressures, optional variants with reduced spring force (EC04) are recommended. Pressure data [bar]: Overpressure to atmospheric pressure. Static: When closed, the valve is pressurised on one side with the maximum operating pressure.
Any installation position, preferably with the actuator facing up. The following installation positions are recommended for the installation of T-valve bodies in circular pipelines:
For supply of medium:

For removal of medium:

DANGER
Damage to the diaphragm or the actuator. The diaphragm and actuator can be damaged when welding the valve body into the pipeline. In the case of devices with a welded connection, remove the actuator and diaphragm from the valve body before installation.
| Diaphragm size | Tightening torques EPDM, FKM [Nm] | Tightening torques PTFE, GYLON® [Nm] |
|---|---|---|
| 8 | 2 | 2.5 |
| 15 | 3.5 | 4 |
| 20 | 4 | 4.5 |
| 25 | 5 | 6 |
| 40 | 8 | 10 |
| 50 | 12 | 15 |
| 65 | 20 | 30 |
| 80 | 30 | 40 |
| 100 | 40 | 50 |