Skip to content
IP54Up to 22 barStepper Motor Actuator

BURKERT 20077710 3280 Electromotive 2-Way Globe Proportional Valve

Burkert Type 3280 electromotive 2-way globe proportional valve features a stepper motor actuator, excellent setting range, low power consumption, and pressure range up to 22 bar.

BURKERT 20077710 3280 Electromotive 2-Way Globe Proportional Valve

Burkert Type 3280 direct-acting electromotive 2-way globe proportional valve is suitable for dosing liquids and gases in closed or open control loops. The valve is driven by a linear stepper motor. The integrated electronics assembly simplifies process integration, eliminating the need for additional actuation modules. The motor requires no energy to maintain a specific valve opening, which can dramatically reduce the energy consumption of a plant and improve efficiency. Type 3280 is available as a standard on/off or proportional valve, as a variant with an integrated positioner, and as a variant with an integrated process controller.

General Technical Data

PropertyValue
OrificeDN 1 to DN 10, NPS 1/4, 3/8, 1/2
Flow directionAgainst closing direction (below seat)
DesignGlobe on/off valve, Globe control valve
Weight~0.7 kg
Operating pressure0...6 bar(g) (Standard); High pressure variant up to 22 bar(g) optionally available
Duty cycleUp to 100% (depending on medium and ambient temperature)
Operating voltage24 V DC ± 10% (max. residual ripple 10%)
Power consumption<1 W in holding position; Max. 8 W (DN 1...DN 6) resp. max. 12 W (DN 8 and DN 10, as well as high-pressure variants)
Operating mediumNeutral gases and liquids
Medium temperatureEPDM: -30 °C...+70 °C; FKM, NBR: 0 °C...+70 °C
Ambient temperature-10 °C...+60 °C (Derating applies)
Degree of protectionIP54

Materials

Note

The globe control valve Type 3280 is supplied with various port connections. These connections are not shown completely. However, they correspond to the material of the valve housing.

BURKERT 20077710 Burkert 3280 material specifications and components

Actuator

No.ElementMaterial
1Housing coverPC (Polycarbonate)
2Housing basePPS (Polyphenylenesulfide)

Valve body

No.ElementMaterial
3Spindle sealFKM/EPDM/NBR
4SpindleStainless steel 1.4305
5Upper valve bodyBrass or stainless steel 1.4305
6Piston with parabolic control elementPTFE / Stainless steel 1.4305
7Elastomer seat sealFKM/EPDM/NBR
8O-ringFKM/EPDM/NBR
9SeatStainless steel 1.4301/1.4305
10Valve bodyBrass or stainless steel AISI 316L

Dimensions

Threaded Variant

BURKERT 20077710 Burkert 3280 threaded variant dimensions table

ABCDEFGH
--12G 3/897.4137.21227.5
610.3-NPT 3/897.4137.21227.5
--12G 1/496.4134.21027.5
5.810-NPT 1/496.4134.21027.5
--14G 1/297.4139.21429.5
8.213.7-NPT 1/297.4139.21429.5

Performance Specifications

Duty Cycle Derating

Note

  • The duty cycle is an important factor for motor valves. The self-heating of the engine limits the maximum duty cycle. High ambient temperatures additionally increase the risk of damage due to overheating.
  • The duty cycle does not mean the duty cycle of the device but the duty cycle of the motor. This is only switched on when the valve is to move.
  • Operating the valve outside the recommended duty cycle limits will result in a significantly reduced service life of the valve.

BURKERT 20077710 Burkert 3280 duty cycle derating diagram

Pressure Range

Standard Variant

Valve functionSeat sizePort connectionKvs-value [m³/h]Pressure range [bar(g)]
Control valve, without safety position in case of power failure1G 1/40.0300...6
1.5G 1/40.0650...6
2G 1/40.1300...6
3G 1/40.3000...6
4G 3/80.5000...6
5G 3/80.7500...6
6G 3/80.9000...6
8G 1/21.5000...6
10G 1/21.9000...6

High-Pressure Variant

Valve functionSeat sizePort connectionKvs-value [m³/h]Pressure range fluid media [bar(g)]Pressure range gaseous media [bar(g)]
Control valve, without safety position in case of power failure1G 1/40.0300...150...22
1.5G 1/40.0650...150...22
2G 3/80.1300...150...22
3G 3/80.3000...150...22
4G 3/80.5000...120...12
5G 3/80.7500...120...12
6G 3/80.9000...150...16
8G 1/21.5000...120...12
10G 1/21.9000...100...10

Flow Characteristic

Note

The dimensioning of the seat size is very important for electromotive proportional valves to function properly within the application. The seat size must be selected so that the desired flow range is achieved and, when the valve is fully open, a sufficient portion of the total pressure drop occurs across the valve. Reference value: Δp valve > 25% of the total pressure drop.

BURKERT 20077710 Burkert 3280 exemplary characteristic curve of the motor valve

Product Operation

Standard on/off valve In the on/off variant, an external voltage signal is digitized and the valve is closed or opened. The status of the two end positions of the valve are indicated on the LED. In addition, the valve position "closed" is reached via the digital output.

Standard control valve The standard proportional valve converts an external standard signal (position set-point value) into a valve position. Both valve end positions are indicated by the LED status. Additionally, the digital output indicates when the "closed" valve position has been achieved.

BURKERT 20077710 Burkert 3280 process diagram for standard and control variants

Positioner variant The proportional valve in the position control variant converts an external standard signal, the position set-point value, into a valve position. The position of the actuator is controlled according to the set-point position. The position sensor records the current position (POS) of the electromotive valve. This actual position is compared by the positioner with the set-point value (CMD) specified as the standard signal.

Process controller variant The additionally implemented PID controller can perform not only the actual position control but also a process control in the sense of a cascade control. The position setpoint of the valve is calculated from the process setpoint and the actual process value via the control parameters (PID controller).

Electrical Connection

Pin assignment analogue (Circular plug M12, 8-pin)

PinConfiguration
124 V DC
2Power supply GND
3Internal use
4Internal use
5Internal use
6Signal input +
7Signal output
8Signal GND

Pin assignment digital / fieldbus (Circular plug M12, 5-pin)

PinConfiguration
1Shield
224 V DC
3GND
4CAN_H
5CAN_L