Skip to content
ATEX / IECEx Zone 2PROFINET S2IP65 (in cabinet)Hot Swap

BURKERT 20140991 8652 AirLINE Valve Island

Burkert Type 8652 AirLINE valve island optimised for process automation. Features LC display diagnostics, PROFINET S2, ATEX/IECEx Zone 2 approvals, and AirLINE Quick adapter for compact control cabinet installation.

BURKERT 20140991 8652 AirLINE Valve Island

Burkert Type 8652 AirLINE valve island has been especially developed for process automation requirements. New diagnostic functions can be visualised on the LC display, both in clear text as well as symbols. This makes it easy to relate to the shown messages and helps to save time during start-up and maintenance. Furthermore, the diagnostic message is also available at the controller, enabling a fast overview of the plant status.

The hardware is optimised for installation at the bottom of the control cabinet. Installation on a standard rail is also possible. Key pneumatic functions ensure increased process reliability, such as check valves in the exhaust air ducts that prevent unplanned actuation due to pressure peaks.

BURKERT 20140991 Burkert 8652 AirLINE valve island overview

General Technical Data

Product properties
Body materialPA (polyamide)
Seal materialNBR and PUR
Width per station11 mm
Number of valve slotsMax. 24
Maximum number of valve functionsMax. 48
Pressure rangeVac...10 bar
External supply air (auxiliary pilot air)3...10 bar
Flow rate QNn value air310 l/min (measured at +20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure)
Operating voltage24 V DC (±10% tolerance)
Nominal power of each valve0.7 W (0.175 W after power reduction)
Operating mediumOil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended)
Degree of protectionIP20, IP65 in closed control cabinets
Ambient temperature-10 °C...+55 °C

AirLINE Quick

AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve terminal is adapted directly to the control cabinet floor or control cabinet wall.

  • Reduced space requirement in the control cabinet
  • This makes it possible to use more compact control cabinets
  • Reduced installation effort due to hose connections directly at the bottom of the control cabinet

BURKERT 20140991 Burkert 8652 AirLINE Quick adapter plate

Approvals and Conformities

  • Explosion protection: ATEX (II 3G Ex ec IIC Gc, II 3D Ex tc IIIC Dc), IECEx (Ex ec IIC Gc, Ex tc IIIC Dc). Suitable for zone 2/22.
  • North America: UL Listed (UL 61010-1), UL Recognized for Hazardous Locations (Class I, Zone 2; Class II, Zone 22; Class I, Div 2).
  • China: China Compulsory Certification (CCC) for hazardous applications.

Dimensions

Variant 4-, 8- and 12-fold

BURKERT 20140991 Burkert 8652 dimensions for 4, 8, and 12-fold variants

Variant 16-, 20- and 24-fold

BURKERT 20140991 Burkert 8652 dimensions for 16, 20, and 24-fold variants

Product Installation

To use the Hot Swap function, always observe a minimum distance to the front edge of the control cabinet when installing the valve island inside the control cabinet.

BURKERT 20140991 Burkert 8652 installation clearance in control cabinet

Example Configuration

The following illustration shows a network with the example of AirLINE Type 8652 with Industrial Ethernet variant as master valve terminal and various AirLINE Type 8652 with büS variant as slave valve terminals.

BURKERT 20140991 Burkert 8652 network configuration example

Safety Instructions for Hazardous Locations

  • Danger from voltage: Do not connect or disconnect when energized in explosive atmospheres. Prevent unintentional restart.
  • Hot Swap: The Hot Swap function is prohibited in explosive atmospheres unless it is ensured by suitable testing equipment that no explosive atmosphere is present.
  • Enclosure: Ensure the device is installed in a suitable enclosure (min. IP54 for 3G/Gc, min. IP64 for 3D/Dc).