Yoshitake DP-18 series pilot-operated diaphragm solenoid valve with stainless steel body and JIS 10K FF flanged connection. Suitable for air, water, and oil.

Yoshitake DP-18 is an ultra-high performance diaphragm-type solenoid valve featuring a stainless steel body and JIS 10K FF flanged connection. Designed for excellent corrosion resistance, it is suitable for air, cold and hot water, and oil.
INFO
The DP-18 series supports both horizontal and vertical installation. For vertical installation, a minimum differential pressure of 0.1 MPa or more is required.

| Specification | Value |
|---|---|
| Application | Air, Cold and hot water, Oil (20 cSt or less) |
| Working pressure | 0–1.0 MPa (unusable under vacuum) |
| Min. differential pressure | 0 MPa (0.1 MPa or more is required for vertical installation) |
| Valve seat leakage | None (by confirming pressure gauge visually) |
| Max. temperature | 60°C |
| Operation | Normally closed (DP-18, DP-18D) Normally opened (DP-18C, DP-18CD) |
| Material (Body) | Stainless steel |
| Material (Valve) | NBR (diaphragm) |
| Connection | JIS 10K FF flanged |
| Rated voltage | AC100/200V AC110/220V (50/60 Hz common) | DC24V |
|---|---|---|
| Voltage fluctuation tolerance | Rated voltage ±10% | Rated voltage ±10% |
| Rated current | 0.42/0.21 A (100/200V) 0.38/0.19 A (110/220V) | 1.13 A |
| Starting current | 1.64/0.82 A (100/200V) 1.48/0.74 A (110/220V) | - |
| Insulation type | Class H | Class H |
| Protection structure | Dust-proof, Splash-proof | Dust-proof, Splash-proof |
| Degree of protection | IP64 | IP64 |
| Insulation resistance | More than 50 MΩ / 500V megger | More than 50 MΩ / 500V megger |
| Anti-voltage test | 1500 V/min | 1500 V/min |
INFO
The DP-18 series utilizes a welded flanged structure.
DP-18 (AC Coil, Normally Closed)
| Nominal size | d | L (mm) | H (mm) | H1 (mm) | Weight (kg) |
|---|---|---|---|---|---|
| 15A | 15 | 120 | 142.5 | 47.5 | 2.6 |
| 20A | 20 | 130 | 149.0 | 50.0 | 3.2 |
| 25A | 25 | 145 | 165.0 | 62.5 | 4.7 |
| 32A | 32 | 160 | 192.0 | 67.5 | 6.5 |
| 40A | 40 | 170 | 198.0 | 70.0 | 7.2 |
| 50A | 50 | 195 | 213.0 | 77.5 | 9.9 |
DP-18C (AC Coil, Normally Opened)
| Nominal size | d | L (mm) | H (mm) | H1 (mm) | Weight (kg) |
|---|---|---|---|---|---|
| 15A | 15 | 120 | 205 | 47.5 | 2.9 |
| 20A | 20 | 130 | 212 | 50.0 | 3.5 |
| 25A | 25 | 145 | 228 | 62.5 | 5.0 |
| 32A | 32 | 160 | 255 | 67.5 | 6.8 |
| 40A | 40 | 170 | 261 | 70.0 | 7.5 |
| 50A | 50 | 195 | 276 | 77.5 | 10.2 |
DP-18D (DC Coil, Normally Closed)
| Nominal size | d | L (mm) | H (mm) | H1 (mm) | Weight (kg) |
|---|---|---|---|---|---|
| 15A | 15 | 120 | 157 | 47.5 | 3.4 |
| 20A | 20 | 130 | 164 | 50.0 | 4.0 |
| 25A | 25 | 145 | 180 | 62.5 | 5.5 |
| 32A | 32 | 160 | 207 | 67.5 | 7.3 |
| 40A | 40 | 170 | 213 | 70.0 | 8.0 |
| 50A | 50 | 195 | 228 | 77.5 | 10.7 |
DP-18CD (DC Coil, Normally Opened)
| Nominal size | d | L (mm) | H (mm) | H1 (mm) | Weight (kg) |
|---|---|---|---|---|---|
| 15A | 15 | 120 | 205 | 47.5 | 3.6 |
| 20A | 20 | 130 | 212 | 50.0 | 4.2 |
| 25A | 25 | 145 | 228 | 62.5 | 5.7 |
| 32A | 32 | 160 | 255 | 67.5 | 7.5 |
| 40A | 40 | 170 | 261 | 70.0 | 8.2 |
| 50A | 50 | 195 | 276 | 77.5 | 10.9 |
Selection Chart (For Air)

How to use the chart: When selecting the nominal size of a solenoid valve whose inlet pressure (P1), outlet pressure (P2), and air (20°C) flow rate (Q) are 0.5 MPa, 0.35 MPa, and 600 m³/h (standard condition), respectively, first find intersection point (a) of P1 = 0.5 MPa and P2 = 0.35 MPa. Trace down vertically from this intersection point (a) to find intersection point (b) with Q = 600 m³/h (standard condition). Since this intersection point (b) lies between nominal sizes 20A and 25A, select the larger one, 25A.
Selection Chart (For Water)

How to use the chart: When selecting the nominal size of a solenoid valve whose inlet pressure (P1), outlet pressure (P2), and flow rate (V) are 0.7 MPa, 0.5 MPa, and 300 L/min, first find the intersection point (a) of the differential pressure before and after the valve [ΔP = 0.7 - 0.5 = 0.2 MPa] and V = 300 L/min. Since this intersection point (a) lies between nominal sizes 25A and 32A, select the larger one, 32A.