Yoshitake GD-56-80, GD-55-80 Water Pressure Reducing Valve

Yoshitake GD-56-80 and GD-55-80 water pressure reducing valves for hot water heat exchangers. Featuring pressure balance structure, built-in 60 mesh strainer, back-flow prevention, and 80 kPa standard set pressure.

Yoshitake GD-56-80, GD-55-80 Water Pressure Reducing Valve

Yoshitake GD-56-80 home boiler regulator is mainly used for water supply to hot water heat exchangers. It maintains a stable water supply pressure in order to prevent the heat exchanger body from high pressure.

Not just pressure reducing but also has functions of back-flow prevention, negative pressure operation, pressure balancing and a built-in strainer.

Features

  1. The valve is pressure balance structure.
  2. Pipes can be installed either horizontally or vertically.
  3. Valve and diaphragm are made of chlorine resistance synthetic rubber.

Yoshitake GD-56-80 valve appearance

Yoshitake GD-56-80 valve cross section

Specifications

ApplicationCold and hot water
Inlet pressure100-750 kPa
Standard set pressure80 ± 6 kPa
BodyBronze
DiaphragmSynthetic rubber
Valve · Check valveSynthetic rubber
StrainerScreen: Stainless steel
Frame: Synthetic resin
Strainer mesh60 mesh
Maximum temperature60°C
ConnectionJIS Rc screwed
Install directionHorizontal and vertical

Available Variants

  • Standard set pressure 65 kPa (JIS approved) is available for GD-55-65 and GD-56-65.
  • Standard set pressure 30-200 kPa is available for GD-55 and GD-56.

Performance

Open flow rate30 L/min or more
Closing pressure of back-flow prevent function3 kPa or less
Operate pressure of negative pressure operating functionOpen: -55 kPa or less
Close: 50 kPa or more

Open flow rate indicates the outlet flow rate when the inlet pressure is maintained at 100kPa and the outlet side is open.

Dimensions and Weights

Yoshitake GD-56-80 dimensions drawing

Yoshitake GD-56-80 dimensions table

Characteristic Charts

Pressure Characteristic Chart

Yoshitake GD-56-80 pressure characteristic chart

Flow Characteristic Chart

Yoshitake GD-56-80 flow characteristic chart

Maximum Pressure of Water Pressure Reducing Valve, Relief Valve and Hot Water Heat Exchanger

Water pressure reducing valveRelief valve for hot water makerMax. pressure of hot water heat exchanger
8095, 97100
8597100
120190200
150190200
170190200

(Unit: kPa)

Attention

Using the bold font valves to simple boiler (100 kPa) is illegal.

Piping Example

Yoshitake GD-56-80 piping example

Precautions for Installation and Operation

  1. Clean up inside the pipe and remove foreign substances before installing the home boiler regulator.
  2. Water may leak from the negative pressure operating mechanism at the first time of water supplying. Please connect vinyl tube and conduct to drain.
  3. Please be sure to remove foreign substances and scales from inside of the piping before connecting the product to the piping.
  4. Install pipe at the relief valve outlet side and conduct to drain ditch. Also install the relief valve so as to check the operation visually.
  5. Relief valve will be opened by lifting the lever horizontally. Please check the operation 1-2 times a month.
  6. Styrofoam package can be used as heat insulating material to prevent freezing.

Parts List

Yoshitake GD-56-80 parts drawing