GP, GD, and CP series for stable pressure reduction and control in steam, water, and air systems.
Compare only the points that determine the choice: function or construction, applicable medium, operating range, body material, and connection or nominal size. Open the model page to confirm the full specification.
| Model | Key selection point | Medium | Operating range | Body material | Connection / size |
|---|---|---|---|---|---|
| GP-1000 | Pilot-Operated Steam Pressure Reducing Valve | Steam | 0.1 - 1.0 MPa (Standard) 220℃ | — | JIS 10K FF Flanged; Standard, JIS 10K FF flanged |
| GP-1010 | Pilot-Operated Pressure Reducing Valve for Steam | Steam | 0.1 - 1.0 MPa 220°C | — | JIS Rc Screw; JIS Rc screwed, Ductile cast iron body |
| GP-1000SS | Pressure Reducing Valve for Steam | Steam | 0.1-1.0 MPa 220°C | — | JIS 10K FF flanged; Stainless steel wetted parts |
| GP-1000H | GP-1000HEN Pilot-Operated Pressure Reducing Valve | Steam | 0.1 - 1.6 MPa 220°C | Ductile cast iron | JIS 16K FF flanged / ASME Class 300 flanged connection |
| GP-1002 | Pilot-Operated Pressure Reducing Valve for Steam | Steam | 0.1-0.5 MPa 220°C | Ductile cast iron | JIS 10K FF flanged; 0.1-0.5 MPa inlet, JIS 10K FF flanged |
| GP-1012 | — | Steam | 0.1 - 1.0 MPa (Standard) 220℃ | — | JIS 10K FF Flanged; Low pressure, JIS Rc screwed |
| CP-2001 | Combination Valve | Steam | 0.1-1.0 MPa 183℃ | — | JIS Rc screwed / JIS 10K flanged; 0.1-1.0 MPa inlet, Steam |
| CP-2002 | Combination Valve for Steam | Steam | 0.1 - 1.0 MPa 183℃ | — | Combination valve for steam |
| CP-2003 | Steam Combination Valve | Steam | 0.1 - 1.0 MPa 183°C | — | Screwed 15A-50A / Flanged 15A-100A |
| CP-2004 Screwed | — | Steam | 0.1 - 1.0 MPa 183°C | Ductile cast iron | JIS Rc screwed, JIS 10K flanged; JIS Rc screwed connection, 15A-50A |
| CP-2004 Flanged | — | Steam | 0.1 - 1.0 MPa 183°C | Ductile cast iron | JIS Rc screwed, JIS 10K flanged; JIS 10K flanged connection, 15A-100A |
| GD-15 | GD-15C Low-Noise Water Pressure Reducing Valve | City water | 0.1-1.0 MPa 5-60°C | — | JIS Rc screwed; Standard low-noise pressure reducing valve |
| GD-15C | GD-15, 15C Low-Noise Pressure Reducing Valves | City water | 0.1-1.0 MPa 5-60°C | — | JIS Rc screwed; 15A: Rc 1/2 connection, 0.87 kg weight; 20A: Rc 3/4 connection, 0.87 kg weight |
| GD-17 | Pressure Reducing Valve | — | — | — | Rc Threaded (Rc 1/2, Rc 3/4, Rc 1); 15A: Rc 1/2 connection, 90mm length; 20A: Rc 3/4 connection, 90mm length; 25A: Rc 1 connection, 110mm length |
| GD-200 | Pressure Reducing Valve, Ductile Cast Iron | — | 1.0 MPa (GD-200) / 2.0 MPa (GD-200H) | Ductile Cast Iron | JIS 10K FF / 20K RF; 1.0 MPa max inlet pressure, cold/hot water, oil, air |
| GD-200C-N | — | — | 1.0 MPa (GD-200) / 2.0 MPa (GD-200H) | Ductile Cast Iron | JIS 10K FF / 20K RF; Nylon 11 coated, cold/hot water, JWWA approved |
| GD-200H | Pressure Reducing Valve, JIS 20K RF Flanged, 2.0 MPa Inlet | Cold and hot water, Oil (kerosene, heavy oils A and B), Air, Other non-dangerous fluids | 2.0 MPa or less 5-80°C | Ductile cast iron | JIS 20K RF flanged; 15A-150A, JIS 20K RF |
| GD-24 | Water Pressure Reducing Valve | Cold and hot water, Flushing water | 0.2-1.6 MPa 5-80°C | Bronze / Cast bronze | JIS Rc screwed; Standard pressure reducing valve |
| GD-24G | — | Cold and hot water, Flushing water | 0.2-1.6 MPa 5-80°C | Bronze / Cast bronze | JIS Rc screwed; With D-type 1.0MPa pressure gauge |
| GD-24S | — | Cold and hot water, Flushing water | 0.2-1.6 MPa 5-80°C | Bronze / Cast bronze | JIS Rc screwed; With strainer (SY-24, 60 mesh) |
| GD-24GS | Pressure Reducing Valve (Bronze, Water) | Hot or cold water | 0.2~1.6 MPa 5~80 ℃ | Bronze | 15A: JIS Rc connection; 20A: JIS Rc connection; 25A: JIS Rc connection; 32A: JIS Rc connection; 40A: JIS Rc connection; 50A: JIS Rc connection |
| GD-25GJ-K | Water Pressure Reducing Valve | City water | 1.0 MPa or less 5-90℃ (GD-25GJ-K) / 5-40℃ (GD-25GJ-L) | — | JIS Rc 1 screwed (union joint); For general piping, 5-90℃ fluid temperature |
| GD-25GJ-L | — | City water | 1.0 MPa or less 5-90℃ (GD-25GJ-K) / 5-40℃ (GD-25GJ-L) | — | JIS Rc 1 screwed (union joint); Built-in pipe end core, 5-40℃ fluid temperature |
| GD-26-NE | Pressure Reducing Valve | Cold and hot water | 1.0 MPa or less 5 - 90°C | Cast Bronze (NPb-treated) | JIS Rc screwed; 15A: Rc 1/2; 20A: Rc 3/4; 25A: Rc 1; 32A: Rc 1-1/4; 40A: Rc 1-1/2; 50A: Rc 2 |
Yoshitake pressure-reducing valves span direct-operated, pilot-operated, air-service, water-service, stainless-steel, and solenoid-assisted steam configurations. Select first by medium and required inlet-to-outlet pressure range, then by flow capacity, required control stability, material, connection, and failure response.
This guide groups local Yoshitake catalogue pages for preliminary engineering review. The model-specific Yoshitake documentation, sizing calculation, materials confirmation, and applicable site requirements control the final order and installation decision.
Open a model page for specifications, connection options and technical documents.