The Yoshitake PG-2 is a stainless steel pressure gauge featuring a Bourdon tube design. Suitable for steam, air, gas, and liquid applications up to 60°C.

The Yoshitake PG-2 is a pressure gauge featuring a structure that transmits the elastic deformation of the Bourdon tube to the pointer. Constructed with a stainless steel case, Bourdon tube, and spanner flats, it offers excellent corrosion resistance. The PG-2 is suitable for steam, air, gas, and liquid applications, providing reliable pressure measurement across various industrial systems.
| Feature | Specification |
|---|---|
| Model | PG-2 |
| Application | Steam, gas, liquid |
| Maximum temperature | 60°C |
| Size | Φ 100 |
| Case shape | Type A |
| Pressure range | 0 to 0.25 / 0.4 / 0.6 / 1.0 / 1.6 / 2.5 / 4.0 MPa 0 to 2.5 / 4.0 / 6.0 / 10 / 16 / 25 / 40 bar (Dual scale dial indicates pressure in bar and psi.) |
| Material (Case) | SUS (Stainless steel) |
| Material (Bourdon tube) | SUS (Stainless steel) |
| Material (Spanner flats) | SUS (Stainless steel) |
| Connection | G3/8, BSPT1/2, NPT1/2 |
Application Notes
| Scale range A | Scale range B |
|---|---|
| ±1.6 | ±2.4 |
Value of acceptable tolerance is expressed in percentage of pressure span (all scale range).

Caution
Please confirm that the indications on the product correspond with the specifications of the ordered product model before use. If they are different, do not use the product.
Dimensions of the product with screw connection G3/8

Dimensions of the product with screw connection BSPT1/2・NPT1/2

Delivery and Storage
Installation Warnings
If the product is used on a line with a high frequency of pressure fluctuation, it will cause the product to malfunction. Please take measures before applying pressure fluctuation directly to the pressure gauge.

Operation Warnings
Operation Cautions
| Trouble | Cause | Remedy |
|---|---|---|
| Pointer does not work. | 1. Pressure is not applied. 2. Piping is clogged by foreign substance. | 1. Apply pressure. 2. Remove foreign substance. |
| Accidental error is large. | 1. Fluid exceeds usable temperature range. 2. Head difference due to difference of height. 3. Abrasion of internal structure due to heavy vibration or pressure fluctuation. | 1. Lower temperature. 2. Correct the head. 3. Replace with a new one. |
| Response is slow. | 1. Too much tightening of dampener. 2. Piping is too thin for viscosity of fluid. | 1. Make appropriate tightening. 2. Make the piping thick. |
| Pointer does not point zero when the product is removed from piping. | 1. Deformation of bourdon tube due to over pressure. 2. Clogging of foreign substance in fluid. 3. Abrasion of internal structure due to heavy vibration or pressure fluctuation. | 1. Replace with a new one. 2. Remove foreign substance. 3. Replace with a new one. |
| Off the scale | 1. Deformation of bourdon tube due to over pressure. 2. Gap of pointer and deformation of bourdon tube due to impact. | 1. Replace with a new one. 2. Replace with a new one. |
Maintenance Warnings
Maintenance Cautions