Yoshitake STC-1 Steam Trap Checker

Yoshitake STC-1 steam trap checker. Features automatic diagnosis, surface temperature measurement (0-300°C), and auscultation mode. Speedy 2-8s diagnosis with LCD and LED indicators.

Yoshitake STC-1 Steam Trap Checker

Yoshitake STC-1 is a simple checker that diagnoses the condition of steam traps. It is equipped with automatic steam trap diagnosis, operation auscultation, and steam piping surface temperature sensor functions, enabling speedy and accurate evaluation in various environments.

Features

  • Easy to handle: Realizes diagnosis with simple 2-step operation. Consecutive diagnosis is possible under the same conditions.
  • Short diagnosis time: Takes only 2 or 8 seconds for automatic diagnosis.
  • Vibration function: Start and completion of diagnosis is notified by a vibrator, reducing misdiagnosis and enabling use in blind situations like dark or narrow places.
  • LED function: Diagnosis result can be confirmed on a large LCD screen and LED display. LED turns on when diagnosis completes.
  • Switchable functions: Surface temperature sensor function and auscultation function can be used arbitrarily. Leakage and clogging of other steam valves besides the steam trap can also be detected.

Yoshitake STC-1 product view

Specifications

SpecificationValue
ModelSTC-1
Steam trap automatic diagnosis time2 seconds or 8 seconds
Working pressure for automatic diagnosis0.05 - 8.0 MPa
Working temperature for surface sensing0 - 300 °C
Ambient temperature0 - 40 °C (Non-Freezing)
Automatic power offAfter 5 minutes (while in diagnosis mode and not in operation)
Where to useInside and outside (should not be exposed to rain water)
BatteryDC1.5V AAA alkaline batteries 2pcs
Continuous operating timeApproximately 8 hours
Weight214g (including batteries) / 235g (without batteries in some regions)
AccessoriesStorage case, sensor cap, earphones

Dimensions and Weight

Yoshitake STC-1 dimensions and weight

Mode (Function)

Mode (Function)Overview
Steam trap automatic diagnosis modeAutomatically diagnoses the conditions of steam traps.
Surface temperature sensor modeIndicates the surface temperature of steam piping.
Auscultation modeListens to the conditions of the steam trap.

Results of Automatic Diagnosis

ResultWorking conditions of steam trapLED color
GOODGood conditionGreen
CAUTIONHard to judge whether GOOD or LEAK. Caution required for the possibility of LEAK.Yellow
LEAKHigh possibility of steam leakageRed
LOW TEMP.High possibility of clogged, not in service, or inadequately low capacity, because the surface temperature is low.Yellow

Name of the Parts

Yoshitake STC-1 name of the parts

Manual operation buttonOperation description
POWER/MODE buttonPower ON/OFF: Press down the button for 2 seconds or more.
Switch the mode: Steam trap automatic diagnosis → Surface temperature sensor → Auscultation
TRAP ButtonSelect a steam trap type: DISC → BUCKET → FLOAT → THERMO → OTHERS
▲·▼ ButtonSelect a pressure range. Adjust Volume. Back light ON/OFF.
START ButtonStart steam trap automatic diagnosis.

WARNING

STC-1 cannot be used to check steam traps for tracing lines.

Structural Breakdown

Yoshitake STC-1 drawing parts breakdown

No.Name of PartsMaterialsQ.TY
1BodySynthetic Resin etc1
2Sensor CapSynthetic Resin1
3Battery CoverSynthetic Resin1
4Battery Cover GasketSilicone Rubber1
5Rubber CapSilicone Rubber1
6Product Label-1
7Serial Number Label-1
8Earphone-1
9Alkaline Battery-2
10Carry Case-1

Procedures for Steam Trap Automatic Diagnosis Mode

  1. Choose "Steam trap automatic diagnosis mode" by pressing the "POWER/MODE" button.
  2. Select the type of steam trap by pressing the "TRAP" button.
  3. Select the pressure range by pressing the "▲ · ▼" button.

Table 1: Pressure range

NoPressure Range
10.05 MPa or more and less than 0.1 MPa
20.1 MPa or more and less than 0.5 MPa
30.5 MPa or more and less than 1.0 MPa
41.0 MPa or more and less than 2.0 MPa
52.0 MPa or more and less than 3.0 MPa
63.0 MPa or more and less than 4.0 MPa
74.0 MPa or more and less than 5.0 MPa
85.0 MPa or more and less than 6.0 MPa
96.0 MPa or more and less than 7.0 MPa
107.0 MPa or more and less than 8.0 MPa
  1. Press the sensor tip vertically against the inlet side (flat surface) of the steam trap.

Yoshitake STC-1 sensor tipYoshitake STC-1 when sensor tip is pressed

TIP

During the steam trap diagnosis, press the sensor tip as vertically as possible. If the sensor tip is pressed from an angle, the contact condition will change and accurate measurement will not be possible. It is recommended to create a flat surface by sanding the measurement surface.

  1. Press the "START" button to start the steam trap diagnosis. Vibration will notify you of the starting of the measurement.
  2. The diagnosis completes with vibrator operation (after 2 seconds or 8 seconds).
  3. The screen displays the diagnosis result, and the LED turns on for about 5 seconds.