Yoshitake SY-9 Y-type strainer in ductile cast iron (FCD450). Features an easy plug for residual pressure relief, high flow rate, 1.0 MPa max pressure, and standard 60 mesh filter.

The Yoshitake SY-9 is a light-weight and compact Y-type strainer used for dust prevention in various pipelines. It features a high-flow-rate marine type design with the largest possible filtration area to minimize the decrease in flow rate caused by clogging. Disassembling and cleaning are easy, as the easy plug relieves residual pressure, making cap removal simple and safe.

| Application | Air, Cold and hot water, Other non-dangerous fluids |
|---|---|
| Max. pressure | 1.0 MPa |
| Max. temperature | 80°C |
| Connection | JIS Rc screwed |
| Body Material | Ductile cast iron (FCD450) |
| Screen Material | Stainless steel |
| O ring | FKM (Viton) |
| Cap | C3604 (Brass) |
| Perforation | φ2.5-4P |
| Mesh | Standard 60 mesh |
INFO
Products with 20 to 100 mesh filters are also available upon request. The size of the Easy-plug's cross-hole is φ10.


| Size | d | L (mm) | H1 (mm) | ds (mm) | ls (mm) | A (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| 15A | Rc 1/2 | 75 | 70 | 20 | 35 | 21.8 | 0.7 |
| 20A | Rc 3/4 | 90 | 84 | 25 | 50 | 26.8 | 0.9 |
| 25A | Rc 1 | 110 | 96 | 32 | 60 | 30 | 1.7 |
| 32A | Rc 1 1/4 | 135 | 114 | 40 | 70 | 36 | 2.8 |
| 40A | Rc 1 1/2 | 145 | 120 | 45 | 75 | 41 | 4.0 |
| 50A | Rc 2 | 170 | 131 | 56 | 90 | 46 | 5.1 |

| No. | Part Name | Material |
|---|---|---|
| 1 | Body | Ductile Cast Iron (FCD450) |
| 2 | Cap | Brass (C3604) |
| 3 | Screen | Stainless Steel (SUS304) |
| 4 | O Ring | FKM |
| 5 | Cross recessed head screws | Stainless Steel (SUS) |
| 6 | Spacer | Brass (C3604) |
| 7 | Spring | Stainless Steel (SUS) |
Dust, scale, and other foreign substances flowing into the product through the inlet port are removed by the screen.
Select a nominal size of the product equivalent to that of the pipe. Using a smaller nominal size increases the pressure loss through the strainer, which may possibly reduce the equipment inlet pressure below the specified limit.
| Fluid | Remarks | Standard flow velocity |
|---|---|---|
| Air (Lower pressure) | 15 m/s [5-15] | |
| Air (Extremely low pressure) | 0.1 MPa or less | 10 m/s [3-10] |
| Water | 2 m/s [2-4] |
Screen: φ2.5-4P perforations with 60 mesh filter


WARNING
| Size | H (mm) |
|---|---|
| 15A | 80 |
| 20A | 100 |
| 25A | 110 |
| 32A | 130 |
| 40A | 140 |
| 50A | 160 |

Before Operation
Before letting the fluid into the product, make sure that there is no possibility of danger when the fluid flows into the ends of piping. Spouting hot fluid may scald skin.
TIP
Use the product with a maximum pressure loss below 0.1 MPa. Periodically clean the screen to prevent damage. Clogging can be monitored when pressure gauges are installed in upstream and downstream of the strainer.
WARNING

When reassembling, replace the O ring with a new one, and securely fasten the cap to the specified torque.
| Nominal size | Size of O Ring | Specified torque value (N·m) |
|---|---|---|
| 15A | P26 | 6 |
| 20A | P32 | 6 |
| 25A | P40 | 6 |
| 32A | G50 | 10 |
| 40A | G55 | 10 |
| 50A | G65 | 20 |
| Trouble | Cause | Remedy |
|---|---|---|
| Fluid does not flow | 1. Screen is clogged. 2. Stop valves are closed. | 1. Clean the screen. 2. Open the stop valves. |
| Excessive pressure loss | 1. Screen is clogged. 2. Pressure gauge is out of order. 3. Nominal size is too small. | 1. Clean the screen. 2. Replace pressure gauge. 3. Replace product with proper size. |
| Leakage from the cap | 1. O ring is damaged. 2. Cap is loose. | 1. Replace O ring. 2. Tighten with specified torque. |
Yoshitake Instrumentation / Strainers
SY, SU, SW, and ST series strainers for removing line debris and protecting downstream valves and equipment.