Burkert 20010137 Type 8652 AirLINE valve island for process automation. Features 24 valve ports, PROFIBUS DPV1, LC display diagnostics, and pneumatic HotSwap. Rated for -1 to 10 bar and IP20 protection.

The Burkert 20010137 Type 8652 AirLINE valve island has been especially developed for process automation requirements. New diagnostic functions can be visualised on the LC display, both in clear text as well as symbols. This makes it easy to relate to the shown messages and helps to save time during start-up and maintenance. Furthermore, the diagnostic message is also available at the controller, enabling a fast overview of the plant status. The hardware is optimised for installation at the bottom of the control cabinet. Key pneumatic functions ensure increased process reliability, such as check valves in the exhaust air ducts to prevent unplanned actuation due to pressure peaks.

Key Features:
| Product properties | Description |
|---|---|
| Material | Body: PA (polyamide); Seal: NBR and PUR |
| Width per station | 11 mm |
| Manual override | Latching, spring return (optional: lockable) |
| Number of valve slots | Max. 24 (24 PCE for SKU 20010137) |
| Maximum number of valve functions | Max. 48 |
| Pressure range | Vac...10 bar (-1 to 10 bar for SKU 20010137) |
| External supply air | 3...10 bar |
| Flow rate QNn value air | 310 l/min (measured at +20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure) |
| Operating voltage | 24 V DC (Voltage tolerance ±10%) |
| Nominal power of each valve | 0.7 W (0.175 W after power reduction) |
| Operating medium | Oil-free or lubricated compressed dry air, neutral gases (5 μm filter recommended) |
| Ambient temperature | -10 °C...+55 °C |
| Degree of protection | IP20, IP65 in closed control cabinets |
AirLINE Quick considerably reduces the use of components in the control cabinet. With the AirLINE Quick Adapter, the valve terminal is adapted directly to the control cabinet floor or control cabinet wall.
Advantages:

Type 6534 valves are equipped with additional connection terminals. A valve circuit can therefore be interrupted by an external switch. Manual override is not required for these valve variants. To use the shut-off function, connect the terminal to a potential-free contact (mechanical switch or relay).


To use the Hot Swap function, always observe a minimum distance to the front edge of the control cabinet when installing the valve island inside the control cabinet.

The following illustration shows a network with the example of AirLINE Type 8652 with Industrial Ethernet variant as master valve terminal and various AirLINE Type 8652 with büS variant as slave valve terminals.

Danger from Voltage
Danger of Explosion from Electrostatic Charge
Special Conditions for Hot Swap
The use of the Hot Swap function is prohibited in a potentially explosive atmosphere. If it can be proven and ensured with suitable testing equipment that no explosive atmosphere is present for a certain period of time, it is permissible to remove/insert valves using Hot Swap during this time.