Skip to content
Direct-ActingMedia-SeparatedIP65Kick and Drop Coil

BURKERT 20037311 Bürkert Type 0121 Direct-Acting Media-Separated Solenoid Valve

BURKERT 20037311 Type 0121 direct-acting media-separated solenoid valve features a PVDF body, EPDM seal, and G 3/8 connection. Designed for aggressive media with a 0-2 bar pressure range.

BURKERT 20037311 Bürkert Type 0121 Direct-Acting Media-Separated Solenoid Valve

BURKERT 20037311 Type 0121 is a direct-acting, media-separated pivoted armature solenoid valve designed for controlling, shutting off, and dosing neutral and aggressive media. The solenoid actuator and the medium chamber are separated by a diaphragm system, making the valve suitable for critical media such as aggressive acids and lyes. The solenoid coils are molded with a chemically resistant epoxy. This specific 20037311 configuration features a PVDF body, EPDM seals, a G 3/8 internal thread connection, and operates as a 2/2-way normally open (NO) valve. It includes a manual override for start-up and testing, and utilizes Kick and Drop coil technology for energy reduction.

General Technical Data ​

PropertySpecification
OrificeDN 2 to DN 8 (SKU 20037311 is 6.00 mm)
Thermal insulation classEpoxy coil class H
Duty cycle (Plastic body)10% duty cycle (10 min); 100% continuous operation for variant with high-performance electronic
Switching frequencyMax. 100/min with AC; Max. 10/min for UC (high-performance electronic)
Voltage tolerance±10%
ViscosityMax. 37 mm²/s
Degree of protectionIP65 in accordance with DIN EN 60529/IEC 60529 with correctly connected cable plug
InstallationAs required, preferably with actuator upright

Material Specifications ​

The coil system is separated from the medium by a diaphragm. The sectional drawing below illustrates the standard variant construction.

BURKERT 20037311 Type 0121 sectional drawing showing internal materials and components

No.ElementMaterial
1CoilEpoxy
2O-ringFKM, FFKM, EPDM
3Toggle pinPTFE
4SealFKM, FFKM, EPDM
5SeatPTFE, PVC, Stainless steel 1.4401 (PVDF for 20037311)
6Valve bodyPTFE, PVC, Stainless steel 1.4401 (PVDF for 20037311)

Dimensions ​

The following dimensions apply to the standard variant with threaded connections.

BURKERT 20037311 Type 0121 standard variant dimensional drawing

Body materialDBEF
Stainless steelG 1/4893276
PVC / PTFE / PVDFG 3/8913565 (PVC/PVDF) / 76 (PTFE)

Performance Specifications ​

The pressure range and flow rate depend on the circuit function and orifice size. The values below represent the standard variant.

Circuit functionDNKv value water [m³/h]Pressure range AC [bar]Pressure range DC [bar]
A / F20.10...60...3
40.30...40...2
60.60...20...1
81.00...10...0.8
B (Normally Open)20.10...60...3
40.30...40...2
60.60...20...1
81.00...10...0.5

Installation Recommendation

For safe operation of the solenoid valve, a dirt trap (≤ 500 µm) must be installed before the valve inlet. When manual override is locked, the valve cannot be electrically actuated.

WARNING

Do not use the coil as a lever arm during installation. Hold the device on the body using the appropriate open-ended spanner and screw into the pipeline using PTFE tape as a seal material.