BURKERT 20037311 Type 0121 direct-acting media-separated solenoid valve features a PVDF body, EPDM seal, and G 3/8 connection. Designed for aggressive media with a 0-2 bar pressure range.

BURKERT 20037311 Type 0121 is a direct-acting, media-separated pivoted armature solenoid valve designed for controlling, shutting off, and dosing neutral and aggressive media. The solenoid actuator and the medium chamber are separated by a diaphragm system, making the valve suitable for critical media such as aggressive acids and lyes. The solenoid coils are molded with a chemically resistant epoxy. This specific 20037311 configuration features a PVDF body, EPDM seals, a G 3/8 internal thread connection, and operates as a 2/2-way normally open (NO) valve. It includes a manual override for start-up and testing, and utilizes Kick and Drop coil technology for energy reduction.
| Property | Specification |
|---|---|
| Orifice | DN 2 to DN 8 (SKU 20037311 is 6.00 mm) |
| Thermal insulation class | Epoxy coil class H |
| Duty cycle (Plastic body) | 10% duty cycle (10 min); 100% continuous operation for variant with high-performance electronic |
| Switching frequency | Max. 100/min with AC; Max. 10/min for UC (high-performance electronic) |
| Voltage tolerance | ±10% |
| Viscosity | Max. 37 mm²/s |
| Degree of protection | IP65 in accordance with DIN EN 60529/IEC 60529 with correctly connected cable plug |
| Installation | As required, preferably with actuator upright |
The coil system is separated from the medium by a diaphragm. The sectional drawing below illustrates the standard variant construction.

| No. | Element | Material |
|---|---|---|
| 1 | Coil | Epoxy |
| 2 | O-ring | FKM, FFKM, EPDM |
| 3 | Toggle pin | PTFE |
| 4 | Seal | FKM, FFKM, EPDM |
| 5 | Seat | PTFE, PVC, Stainless steel 1.4401 (PVDF for 20037311) |
| 6 | Valve body | PTFE, PVC, Stainless steel 1.4401 (PVDF for 20037311) |
The following dimensions apply to the standard variant with threaded connections.

| Body material | D | B | E | F |
|---|---|---|---|---|
| Stainless steel | G 1/4 | 89 | 32 | 76 |
| PVC / PTFE / PVDF | G 3/8 | 91 | 35 | 65 (PVC/PVDF) / 76 (PTFE) |
The pressure range and flow rate depend on the circuit function and orifice size. The values below represent the standard variant.
| Circuit function | DN | Kv value water [m³/h] | Pressure range AC [bar] | Pressure range DC [bar] |
|---|---|---|---|---|
| A / F | 2 | 0.1 | 0...6 | 0...3 |
| 4 | 0.3 | 0...4 | 0...2 | |
| 6 | 0.6 | 0...2 | 0...1 | |
| 8 | 1.0 | 0...1 | 0...0.8 | |
| B (Normally Open) | 2 | 0.1 | 0...6 | 0...3 |
| 4 | 0.3 | 0...4 | 0...2 | |
| 6 | 0.6 | 0...2 | 0...1 | |
| 8 | 1.0 | 0...1 | 0...0.5 |
Installation Recommendation
For safe operation of the solenoid valve, a dirt trap (≤ 500 µm) must be installed before the valve inlet. When manual override is locked, the valve cannot be electrically actuated.
WARNING
Do not use the coil as a lever arm during installation. Hold the device on the body using the appropriate open-ended spanner and screw into the pipeline using PTFE tape as a seal material.