BURKERT 20092497 Type 2933 manually operated 2/2-way diaphragm valve. Features a forged stainless steel 316L body, EPDM high-temperature diaphragm, and 0-10 bar pressure range.

BURKERT 20092497 Type 2933 manually operated diaphragm valve consists of a manually operated actuator, a diaphragm, and a 2-way valve body. The manual actuator with a plastic or stainless steel handwheel is available with a diaphragm bonnet made of stainless steel or plastic, ensuring reliable use in hygienic or aggressive ambient conditions. The flow-optimised valve body with minimum dead space enables high flow values and a wide range of possible applications. The actuator features a compact, autoclavable design and is equipped with an integrated visual position indicator, a reproducible stroke scale, and an adjustable closing limiter.
| Product Properties | Description |
|---|---|
| Forged steel valve body (VS) | Forged stainless steel 316L/1.4435 BN2 in accordance with DIN EN 10222-5, ASTM A182/A182M, and ASME BPE |
| Diaphragm | EPDM high-temperature (AD), PTFE/EPDM (EA), advanced PTFE/EPDM (EU), laminate of GYLON® and EPDM (ER) |
| Actuator | Stainless steel/PPS, PPS/PPS, stainless steel/stainless steel |
| Standard surface quality (VS) | Internally electrically polished: Ra ≤ 0.38 μm (ASME BPE SF4 / DIN HE4). Internally mechanically polished: Ra ≤ 0.5 μm (ASME BPE SF1) |
| Operating medium | Neutral gases and liquids, highly purified, sterile, aggressive or abrasive mediums |
| Medium temperature (EPDM) | -10 to +143 °C (steam sterilisation +150 °C for 60 min) |
| Ambient temperature | -10 to +130 °C (short-term up to +150 °C), autoclavable |

| No. | Element | Material |
|---|---|---|
| 1 | Handwheel | Polyphenylene sulphide (PPS), stainless steel 1.4308 |
| 2 | Visual position indicator | Polyamide (PA), Stainless steel 1.4305 |
| 3 | Valve spindle | Stainless steel 1.4305 |
| 4 | Diaphragm bonnet | Stainless steel 1.4308, polyphenylene sulphide (PPS) |
| 5 | Diaphragm | EPDM (AD), PTFE/EPDM (EA), advanced PTFE/EPDM (EU), laminate of GYLON® and EPDM (ER) |
INFO
Dimensions in mm, unless otherwise stated. Further information on the draining angle can be found in the supplementary instructions.

DIN EN ISO 1127 / ISO 4200 / DIN 11866 series B
| Diaphragm size | Port connection DN | ∅D1 | s | L | h | H |
|---|---|---|---|---|---|---|
| 8 | 8 | 13.5 | 1.6 | 90 | 9.3 | 18.8 |
| 15 | 10 | 17.2 | 1.6 | 110 | 12.05 | 23.75 |
| 20 | 20 | 26.9 | 1.6 | 119 | 16.0 | 30.3 |
| 25 | 25 | 33.7 | 2.0 | 129 | 19.0 | 37.0 |
| 40 | 40 | 48.3 | 2.0 | 161 | 27.6 | 52.4 |
| 50 | 50 | 60.3 | 2.0 | 192 | 35.5 | 68.3 |

ASME BPE
| Diaphragm size | Port connection Inch | ∅D1 | s | ∅D2 | L | h | H |
|---|---|---|---|---|---|---|---|
| 8 | 1/2" | 12.7 | 1.65 | 25.0 | 89 | 9.3 | 18.8 |
| 15 | 3/4" | 19.05 | 1.65 | 25.0 | 89 | 12.05 | 23.75 |
| 20 | 3/4" | 19.05 | 1.65 | 25.0 | 117 | 16.0 | 30.3 |
| 25 | 1" | 25.4 | 1.65 | 50.5 | 114 | 19.0 | 37.0 |
| 40 | 1 1/2" | 38.1 | 1.65 | 50.5 | 140 | 27.6 | 52.4 |
| 50 | 2" | 50.8 | 1.65 | 64.0 | 159 | 35.5 | 68.3 |

DIN EN ISO 1127 / ISO 4200 / DIN 11866 series B
| Diaphragm size | Port connection DN | ∅D1 | s | L | h | H |
|---|---|---|---|---|---|---|
| 8 | 8 | 13.5 | 1.6 | 90 | 9.85 | 16.6 |
| 15 | 15 | 21.3 | 1.6 | 110 | 14.35 | 25.0 |
| 20 | 20 | 26.9 | 1.6 | 119 | 17.15 | 30.45 |
| 25 | 25 | 33.7 | 2.0 | 129 | 20.55 | 37.4 |
| 40 | 40 | 48.3 | 2.0 | 161 | 29.35 | 53.5 |
| 50 | 50 | 60.3 | 2.0 | 192 | 35.35 | 65.5 |

DIN 32676 series B (ISO pipe)
| Diaphragm size | Port connection DN | ∅D1 | s | ∅D2 | L | h | H |
|---|---|---|---|---|---|---|---|
| 8 | 8 | 13.5 | 1.6 | 25.0 | 89 | 9.85 | 22.35 |
| 15 | 15 | 21.3 | 1.6 | 50.5 | 110 | 14.35 | 39.60 |
| 20 | 20 | 26.9 | 1.6 | 50.5 | 119 | 17.15 | 42.40 |
| 25 | 25 | 33.7 | 2.0 | 50.5 | 129 | 20.55 | 45.80 |
| 40 | 40 | 48.3 | 2.0 | 64.0 | 161 | 29.35 | 61.35 |
| 50 | 50 | 60.3 | 2.0 | 77.5 | 192 | 35.35 | 74.10 |
| Diaphragm size | Port connection DN | Forged Body (VS) Kv [m³/h] | Tube Body (VP) Kv [m³/h] |
|---|---|---|---|
| 8 | 8 | 1.5 | 1.9 |
| 15 | 15 | 6.5 | 7.2 |
| 20 | 20 | 12.5 | 13.5 |
| 25 | 25 | 18.0 | 20.8 |
| 40 | 40 | 41.0 | 47.9 |
| 50 | 50 | 66.0 | 69.7 |
WARNING
The following tightening torques refer to the static media pressures specified. Excessive torque can shorten the service life of the diaphragm. A tolerance of +10% applies.
| Diaphragm size | Max static operating pressure [bar] | Tightening torque EPDM/FKM [Nm] | Tightening torque PTFE [Nm] |
|---|---|---|---|
| 8 | 10 | 0.6 | 1.1 |
| 15 | 10 | 0.8 | 1.7 |
| 20 | 10 | 0.9 | 3.0 |
| 25 | 10 | 1.2 | 3.5 |
| 40 | 10 | 4.5 | 7.0 |
| 50 | 10 | 6.0 | 11.0 |

TIP
It is the responsibility of the installer and the operator to ensure self-draining. The angle of inclination should correspond to the angle of inclination of the pipeline (recommended according to ASME BPE).
A minimum stroke limit can be set for Type 2933. This setting also serves as a closing limiter to protect the diaphragm.
DANGER
Risk of injury due to high pressure and escaping medium. Switch off the pressure before working on the device or system. Vent or empty the lines.
Explore similar products in our catalog