BURKERT 339597 Type 8745 Mass Flow Controller for CH4 methane. Features 80 Nl/min flow rate, 1/2" NPT internal thread, 4-20 mA signals, and stainless steel body.

BURKERT 339597 Type 8745 is a mass flow controller (MFC) suitable for controlling the mass flow of large gas quantities. The thermal inline sensor located directly in the main gas stream achieves very fast response times with minimal pressure loss. As the actuator, a Bürkert direct-acting proportional valve guarantees high response sensitivity. This specific model is configured for CH4 methane with a nominal flow rate of 80 Nl/min, utilizing a Type 2873 electromagnetic proportional valve and a 1/2" NPT internal thread connection.
| Property | Description |
|---|---|
| Housing Material | PC (polycarbonate) |
| Base Block Material | Stainless steel 1.4404/316L |
| Seal Material | FKM (Fluor rubber) |
| Operating Voltage | 24 V DC (Voltage tolerance ±10%, Residual ripple ±2%) |
| Electrical Connection | D-Sub plug, 9-pin (Analogue variant) |
| Operating Medium | CH4 methane (Real gas calibration) |
| Medium Temperature | -10 °C to +70 °C |
| Port Connection | NPT 1/2" Internal thread |
| Analogue Interface | 4...20 mA (Input/Output) |
| Degree of Protection | IP20 |
This MFC variant uses a direct-acting proportional valve of the 287x series. The electromagnetic proportional valve is normally closed and stands for the highest measuring accuracy and repeatability with settling times of a few hundred milliseconds.
| Performance Data | Value |
|---|---|
| Valve Position | Normally closed |
| Nominal Seat Diameter | 2 mm (5/64") |
| Operating Pressure | Max. 5 bar |
| Measuring Accuracy | ±1.5% MV, ±0.3% FS (under calibration conditions) |
| Repeatability | ±0.1% FS |
| Turndown Ratio | 1:50 |
| Settling Time (t95) | < 500 ms |
Large nominal flow rates, with internal thread
| Thread (A) | Thread depth [mm] |
|---|---|
| NPT 1/2 | 14 |

Variant with electromagnetic proportional valve MFC with valve Type 2873

Analogue Interface (D-Sub plug, 9-pin)

| Pin | Assignment |
|---|---|
| 1 | Digital input |
| 2 | GND (for supply voltage and digital input) |
| 3 | 24 V |
| 4 | Relay, normally closed contact |
| 5 | Relay, reference contact |
| 6 | Set-point value input + |
| 7 | Set-point value input GND |
| 8 | Actual value output + |
| 9 | Actual value output GND |
| Housing | Shielding |
This sensor works as a hot-film anemometer in the CTA operational mode (Constant Temperature Anemometer). Two resistors with a precisely specified temperature coefficient located directly in the media flow and three further resistors are connected to form a measuring bridge. The first resistor in the gas flow measures the fluid temperature, while the second, low-value resistor is always heated just enough to keep it at a fixed, specified excess temperature with respect to the fluid temperature. The heating current required for this is a measure of the heat dissipation and represents the primary measured variable.