TLV SH6NL inline repairable cast steel free float steam trap with three-point seating and thermostatic air venting for superheated or high-pressure steam mains.

TLV SH6NL is an inline repairable cast steel free float steam trap with tight shut-off, designed for the drainage of superheated or high-pressure steam mains and turbines. It features a thermostatic air vent and a three-point seating design to ensure a steam-tight seal even under no-load conditions.
Note on Product Family
While this page focuses on the SH6NL model, the provided maintenance and troubleshooting instructions also apply to the broader SH series (SH3NL, SH5NL, SH5NH, SH6NH, SH5VL) as detailed in the shared instruction manual.
| Model | SH6NL |
|---|---|
| Connection | Socket Welded, Flanged |
| Size | DN 25, 40, 50 |
| Orifice No. | 14, 32, 46, 65 |
| Maximum Operating Pressure (PMO) | 14, 32, 46, 65 barg |
| Maximum Differential Pressure (ΔPMX) | 14, 32, 46, 65 bar |
| Maximum Operating Temperature (TMO) | 425 °C (Socket Welded) / 400* / 425 °C (Flanged) |
PRESSURE SHELL DESIGN CONDITIONS (NOT OPERATING CONDITIONS):
WARNING
To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside of the specification range. Local regulations may restrict the use of this product to below the conditions quoted.
| No. | Description | Material | DIN* | ASTM/AISI* |
|---|---|---|---|---|
| 1 | Body | Cast Steel A216 Gr.WCB | 1.0619 | — |
| 2 | Cover | Cast Steel A216 Gr.WCB | 1.0619 | — |
| 3F | Float | Stainless Steel SUS316L | 1.4404 | AISI316L |
| 4R | Orifice | — | — | — |
| 5MR | Orifice Gasket | Graphite/Stainl. Steel SUS316L | -/1.4404 | -/AISI316L |
| 6R | Air Vent Strip | Bimetal | — | — |
| 7R | Screw & Spring Washer | Stainless Steel SUS304 | 1.4301 | AISI304 |
| 8MR | Cover Gasket | Graphite/Stainl. Steel SUS316L | -/1.4404 | -/AISI316L |
| 9 | Cover Bolt | Alloy Steel SNB7 | 1.7225 | A193 Gr.B7 |
| 10 | Cover Nut | Carbon Steel S45C | 1.0503 | AISI1045 |
| 11R | Screen | Stainless Steel SUS430 | 1.4016 | AISI430 |
| 12 | Screen Holder | Cast Stainless Steel A351 Gr.CF8 | 1.4312 | — |
| 13MR | Screen Holder Gasket | Soft Iron SUYP | 1.1121 | AISI1010 |
| 14 | Orifice Plug | Cast Stainless Steel A351 Gr.CF8 | 1.4312 | — |
| 15MR | Orifice Plug Gasket | Soft Iron SUYP | 1.1121 | AISI1010 |
| 16 | Socket** | Carbon Steel A105 | 1.0460 | — |
| 17 | Flange*** | Carbon Steel A105/Cast Steel A216 Gr.WCB | 1.0460/1.0619 | — |
| 18 | Nameplate | Stainless Steel SUS304 | 1.4301 | AISI304 |
* Equivalent materials. *** Material depends on flange specifications. Replacement kits available: (M) maintenance parts, (R) repair parts, (F) float.

| Size | L | H1* | W* | φB | φD | φC | h | Weight (kg) |
|---|---|---|---|---|---|---|---|---|
| 25 | 178 | 185 | 260 | 180 | 48 | 33.9 | 14 | 21 |
| 40 | 178 | 185 | 260 | 180 | 64 | 48.8 | 14 | 22 |
| 50 | 178 | 185 | 260 | 180 | 76.5 | 61.2 | 17 | 23 |
* ASME B16.11-2005, other standards available. ** Approx.

| DN | L (DIN PN25/40) | L (DIN PN63/100) | L (ASME 150, 300, 600RF) | L (ASME 900RF) | H1* | W* | φB | Weight** (kg) |
|---|---|---|---|---|---|---|---|---|
| 25 | 160 | 230 | 222 | 232 | 185 | 260 | 180 | 26 |
| 40 | 230 | 320 | 270 | 270 | 185 | 260 | 180 | 30 |
| 50 | 230 | 320 | 232 | 310 | 185 | 260 | 180 | 38 |
Other standards available, but length and weight may vary. * Approx. ** Weight is for ASME Class 900 RF.


| No. | Description | No. | Description |
|---|---|---|---|
| 1 | Body | 10 | Cover Nut |
| 2 | Cover | 11 | Screen |
| 3 | Float | 12 | Screen Holder |
| 4 | Orifice | 13 | Screen Holder Gasket |
| 5 | Orifice Gasket | 14 | Flange / Socket |
| 6 | Air Vent Strip | 15 | Nameplate |
| 7 | Screw with Spring Washer | 16 | Orifice Plug |
| 8 | Cover Gasket | 17 | Orifice Plug Gasket |
| 9 | Cover Bolt | 18 | UP-Sticker (SH5VL) |
DANGER
NEVER apply direct heat to the float. The float may explode due to increased internal pressure, causing accidents leading to serious injury or damage to property and equipment.

The face of the screen holder perpendicular to the ground, and the inlet and outlet horizontal to the ground.
IMPORTANT! (For screwed connection)
To prevent rotation due to vibration secure trap in position by supporting the body at the point marked ▲.
| Requirement | Correct | Incorrect |
|---|---|---|
| Install a catchpot with the proper diameter. | Correct diameter | Diameter is too small. |
| Make sure the flow of condensate is not obstructed. | Unobstructed flow | Diameter is too small and inlet protrudes into pipe. |
| To prevent rust and scale from flowing into the trap, connect the inlet pipe 25 - 50 mm (1 - 2 in) above the base of the T - pipe. | Connected above base | Rust and scale flow into the trap with the condensate. |
| When installing on the blind end, make sure nothing obstructs the flow of condensate. | Unobstructed flow | Condensate collects in the pipe. |
Operational inspections should be performed at least twice per year, or as called for by trap operating conditions. Steam trap failure may result in a temperature drop in the equipment, poor product quality or losses due to steam leakage.

| Part | Inspection Item |
|---|---|
| Body, Cover | Check inside for damage, dirt, grease, oil film, rust or scale |
| Gaskets | Check for warping or damage |
| Air Vent Strip | Check for damage |
| Screen | Check for clogging, corrosion or damage |
| Float | Check for deformation, damage, oil film or water inside |
| Orifice | Check for rust, scale, oil film, wear or damage |
| Model | Cover Nut (N·m / mm) | Orifice (N·m / mm) | Orifice Plug (N·m / mm) | Screen Holder (N·m / mm) | Screw (N·m / mm) |
|---|---|---|---|---|---|
| SH3NL | 60 / 17 | 60 / 17 | 200 / 38 | 200 / 38 | 0.3 / + |
| SH5NL | 120 / 22 | 80 / 19 | 200 / 38 | 200 / 38 | 0.3 / + |
| SH6NL | 130 / 22 | 200 / 30 | 400 / 50 | 200 / 38 | 0.3 / + |
| SH5NH | 150 / 22 | 100 / 21 | 200 / 38 | 200 / 38 | 0.3 / + |
| SH6NH | 370 / 30 | 220 / 30 | 400 / 50 | 200 / 38 | 0.3 / + |
| SH5VL | 120 / 22 | 80 / 19 | 300 / 38 | 200 / 38 | 0.3 / + |
A visual inspection can be carried out to aid in determining the necessity for immediate maintenance or repair, if the trap is open to atmosphere. If the trap does not discharge to atmosphere, use diagnostic equipment such as TLV TrapMan.
| Status | Description |
|---|---|
| Normal | Condensate is discharged continuously with flash steam and the sound of flow can be heard. If there is very little condensate, there is almost no sound of flow. |
| Blocked | No condensate is discharged. The trap is quiet and makes no noise, and the surface temperature of the trap is low. |
| Blowing | Live steam continually flows from the outlet and there is a continuous metallic sound. |
| Steam Leakage | Live steam is discharged through the trap outlet together with the condensate and there is a high-pitched sound. |

| Problem | Cause | Remedy |
|---|---|---|
| No condensate is discharged (blocked) or discharge is poor | Float is damaged or filled with condensate | Replace with new float |
| The float is sticking to the orifice | Clean | |
| Orifice, screen or piping is clogged with rust or scale | Clean | |
| Steam locking has occurred | Blowdown through the bypass or close the trap inlet valve and allow the trap to cool | |
| Flow exceeds trap's rated capacity | Check specifications and reselect trap suitable for actual flow | |
| The trap operating pressure exceeds the maximum specified pressure, or there is insufficient differential pressure | Compare specifications and actual operating conditions | |
| Steam is discharged or leaks from the trap outlet (blowing) | Rust and scale have accumulated around the orifice or under the float | Clean |
| Scratches on the orifice | Replace with a new orifice | |
| Float is deformed or coated with scale | Clean or replace the float | |
| Trap is installed above the maximum allowable inclination angle | Correct the installation | |
| Vibration of trap occurs | Lengthen inlet piping, then fasten it securely | |
| The air vent strip is damaged | Replace with a new air vent strip | |
| Steam leaks from a place other than the trap outlet | Deterioration of or damage to gaskets | Replace with new gaskets |
| Improper tightening torque on cover nuts was used | Tighten to the proper torque | |
| Float is frequently damaged | Water hammer occurs | Examine the piping for problems that can cause water hammer |