Armstrong 过热条件下使用的双金属蒸汽疏水阀 – SH-4000 系列 SH-4000 Series Bimetallic Steam Traps for Superheated Steam

Armstrong SH-4000 Series bimetallic steam traps are designed for superheated steam applications. Features an investment cast stainless steel body, handling up to 1,245 psig (86 bar) and 900°F (482°C).

Armstrong 过热条件下使用的双金属蒸汽疏水阀 – SH-4000 系列 SH-4000 Series Bimetallic Steam Traps for Superheated Steam

Armstrong SH-4000 Series Bimetallic Steam Trap is the ideal design for applications involving superheated steam.

During start-up, the bimetallic mechanism is fully open and allows large volumes of non-condensable gases and condensate to be removed from the system. As the system reaches saturated steam conditions, the mechanism begins to close preventing any live steam loss. The superheat during normal operating steam conditions keep the valve closed to ensure long service life.

In the event that operating conditions change and condensate forms at the steam trap inlet, the cooling effect allows the bimetallic mechanism to open and discharge any accumulation. The valve quickly closes once normal operating conditions return.

The SH-4000 consists of an investment cast, stainless steel body that is compact and highly resistant to harsh, corrosive environments. The integral mounting flange is compatible with the Armstrong IS-4, 4-bolt, Class 900, connector making for labor savings and easy steam trap replacement.

Armstrong 过热条件下使用的双金属蒸汽疏水阀 – SH-4000 系列 Armstrong SH-4000 Series bimetallic steam trap exterior view

Maximum Operating Conditions

  • Maximum allowable pressure (vessel design): 86 bar @ 482°C (1245 psig @ 900°F)
  • Maximum operating pressure:
    • SH-4009L: 45 bar @ 482°C (650 psig @ 900°F)
    • SH-4009H: 62 bar @ 482°C (900 psig @ 900°F)
    • SH-4015: 86 bar @ 482°C (1245 psig @ 900°F)

Materials and Weight

ComponentMaterial
BodyASTM A351 Gr. CF8M Stainless Steel
Valve & SeatTitanium
ElementsNi-Cr Stainless Steel
Spiral Wound GasketStainless Steel
BoltsASTM A193 B7
Weight1.7 kg (3.75 lbs)

Specification

Steam traps shall be a bimetallic style designed for superheated steam applications. The steam trap body shall be tamperproof, investment cast stainless steel A351 Gr. CF8M. The mechanism shall consist of a stacked nickel-chrome bimetal operator with titanium valve and seat. The gaskets shall be captured stainless steel spiral wound. The steam trap shall be compatible with the 4-bolt universal connector technology.

Capacity Charts

NOTE

Cold water capacity for start-up loads only. When superheat present, there will be minimal condensate. Grey curve indicates that trap can not be used in this area.

SH-4009L and SH-4009H Cold Water Capacity

Armstrong 过热条件下使用的双金属蒸汽疏水阀 – SH-4000 系列 Armstrong SH-4000 Series SH-4009L and SH-4009H cold water capacity chart

SH-4015 Cold Water Capacity

Armstrong 过热条件下使用的双金属蒸汽疏水阀 – SH-4000 系列 Armstrong SH-4000 Series SH-4015 cold water capacity chart

Product Installation

Before installation, verify that the maximum allowable pressure/temperature and maximum operating pressure of the trap are sufficient to handle the system design pressure and temperature. This information can be found on the label located on the trap.

Steam trap installation is critical from both a performance and maintenance aspect. Installation of the trap is simplified if you follow these guidelines:

  1. Before installing the trap, ensure the line is clean. Blow down any strainers ahead of the trap.
  2. Install the trap so that it is accessible for inspection and repair, below the drip point and close to the vertical drip leg.
  3. The trap must be installed on a 2-bolt or 4-bolt connector block (TVS-4000, IS2 or Standard Connector). Armstrong recommends the trap to be installed in a horizontal line.
  4. Proper piping and drip legs of adequate size and diameter are essential for the successful operation of the Armstrong bimetallic traps.
  5. Isolation valves are needed before and after traps. When starting a new trap, be sure to open the valve slowly.
  6. Due to the high temperatures of steam, it might be necessary to guard the traps for personnel safety.

CAUTION

When working with high pressure/temperature steam, follow safe practices. Superheated steam is invisible. Do not place objects directly in the path of trap discharge.

Drip Leg Sizing

Armstrong 过热条件下使用的双金属蒸汽疏水阀 – SH-4000 系列 Armstrong SH-4000 Series drip leg installation diagram

Steam Main SizeDrip Leg DiameterSupervised Warm-Up (H)Automatic Warm-Up (H)
1/2" (15 mm)1/2" (15 mm)10" (250 mm)28" (700 mm)
3/4" (20 mm)3/4" (20 mm)10" (250 mm)28" (700 mm)
1" (25 mm)1" (25 mm)10" (250 mm)28" (700 mm)
2" (50 mm)2" (50 mm)10" (250 mm)28" (700 mm)
3" (80 mm)3" (80 mm)10" (250 mm)28" (700 mm)
4" (100 mm)4" (100 mm)10" (250 mm)28" (700 mm)
6" (150 mm)4" (100 mm)10" (250 mm)28" (700 mm)
8" (200 mm)4" (100 mm)12" (300 mm)28" (700 mm)
10" (250 mm)6" (150 mm)15" (375 mm)28" (700 mm)
12" (300 mm)6" (150 mm)18" (450 mm)28" (700 mm)
14" (350 mm)8" (200 mm)21" (525 mm)28" (700 mm)
16" (400 mm)8" (200 mm)24" (600 mm)28" (700 mm)
18" (450 mm)10" (250 mm)27" (675 mm)28" (700 mm)
20" (500 mm)10" (250 mm)30" (750 mm)30" (750 mm)
24" (600 mm)12" (300 mm)36" (900 mm)36" (900 mm)

Installing Connector Blocks

Standard Connector The Standard connector block should be installed in piping with the flow direction stamp pointing in the correct direction as indicated on the connector block.

  • The trap will then be bolted to the connector block after the connector block has been installed.
  • When installing the trap to the connector block, apply 35-50 ft-lbs of torque to the bolts using a 9/16” wrench. Allow 2.5” clearance for bolt installation and removal.

RECOMMENDATION

Armstrong strongly recommends adding an upstream strainer and isolation valves upstream and downstream of the trap.

Armstrong 过热条件下使用的双金属蒸汽疏水阀 – SH-4000 系列 Armstrong SH-4000 Series standard connector block installation

IS2 Connector The IS2 connector block should be installed in piping with the flow direction stamp pointing in the correct direction.

Armstrong 过热条件下使用的双金属蒸汽疏水阀 – SH-4000 系列 Armstrong SH-4000 Series IS2 connector block installation

TVS-4000 Connector The TVS-4000/F connector block should be installed in piping with the flow direction stamp pointing in the correct direction. The TVS-4000 has integral strainer and isolation valves.

Armstrong 过热条件下使用的双金属蒸汽疏水阀 – SH-4000 系列 Armstrong SH-4000 Series TVS-4000 connector block installation

Maintenance Requirements

High pressure drips traps should be tested at least three times per year. When the bimetallic steam trap is suspected of malfunctioning, it can be checked by observing the discharge of the trap. Normal trap operation would be indicated by:

  • Trap discharging condensate continuously (modulating)
  • Trap discharge in cycles (on-off)

All discharges are accompanied by large amounts of flash steam. Do not confuse the discharge of flash steam with live steam loss. If the trap continues to blow live steam, isolate the trap and repair or replace.

Troubleshooting

Whenever a trap fails to operate and the reason is not readily apparent, the discharge from the trap should be observed.

1. Cold Trap - No Discharge No condensate or steam coming to trap.

  • a) Stopped or plugged strainer ahead of trap.
  • b) Broken valve in line to trap.
  • c) Pipe line or elbows plugged.
  • d) Pressure reducing valve out of order.
  • e) Isolation valves are off/closed.

2. Steam Loss If the trap leaks or blows live steam, trouble may be due to any of the following causes:

  • a) Valve may fail to seat.
  • b) Piece of scale lodged in orifice.
  • c) Worn parts.
  • Imaginary Troubles: If it appears that steam escapes every time trap discharges, remember: Hot condensate forms flash steam when released to lower pressure, but usually condenses quickly in the return line.

3. Continuous Flow

  • A. Trap not up to temperature. Allow more time for condensate removal (on start-up).
  • B. On large loads the traps is working fine as designed.

If the trap is found defective:

  1. Isolate the trap.
  2. Blow down/bleed off the internal pressure.
  3. With the connector block in line, remove the bolts that hold the trap to the connector block using a 9/16” wrench.
  4. Remove the trap from the connector block.
  5. Replace the failed trap with a working trap.

Repair Parts

SH-4000: Does not have repair parts. If the trap fails, a new one will need to be installed.