Yoshitake GD-47R Primary Pressure Regulating Valve

The Yoshitake GD-47R is a primary pressure regulating valve for steam systems up to 220°C. It features a ductile cast iron body and stainless steel bellows, ideal for heavy-duty boiler and factory use.

Yoshitake GD-47R Primary Pressure Regulating Valve

The Yoshitake GD-47R is a direct/pilot type primary pressure regulating valve designed for steam applications. Equipped with a ductile cast iron (FCD450) body and stainless steel bellows, this pressure sustaining valve provides reliable external sensing control for heavy-duty uses with a wide range of flow rates. It is widely applicable in waste-heat boilers, air conditioning equipment, and various factory facilities.

Yoshitake GD-47R primary pressure regulating valve

Features

  • Applicable on heavy-duty use for the wide range of flow rate.
  • The application of this model is vast such as waste-heat boiler, air conditioning equipment and factory facilities.

Specifications

ApplicationSteam
Nominal size50A
Pressure regulating range0.2-0.9 MPa
Minimum differential pressure0.05 MPa
Application temperature220°C or less
Valve seat leakage0.5% or less of rated flow rate
Primary pressure sensing methodExternal sensing type
Cv value36
ConnectionJIS 10K FF flanged

Materials

PartMaterial
BodyDuctile cast iron (FCD450)
ValveStainless steel
Valve seatStainless steel
BellowsStainless steel

Included Accessories

An external sensing pipe (φ8-2 m) and an external joint (φ8-R 1/4) are included with the product.

Dimensions (mm) and Weight (kg)

Weight: 45 kg

Yoshitake GD-47R dimensions and weight

Flow Characteristic Chart

Yoshitake GD-47R flow characteristic chart

Example of Piping

Yoshitake GD-47R example of piping

Sensing Pipe Connection Method

Connect the provided sensing pipe (φ8-2 m) and joint (φ8-R 1/4) as shown in the illustration above.

  1. Wind sealing tape around the joint and insert the joint into the pressure sensing side.
  2. Fully insert the sensing pipe into the valve and the pressure sensing side joint. Tighten the cap nut until it can no longer be rotated manually, and then turn the cap nut about one and quarter times with a tool.
  3. Sensing pipe should be connected as straight as possible, and should be cut if it is too long.

Cross-Sectional Drawing and Parts List

Yoshitake GD-47R cross-sectional drawing

No.Part NameMaterialStandardQty
28PipeCopperC1220T1
27JointBrassC36042
24Name PlateStainless SteelSUS3041
23GasketCopperC1100P2
22GasketNon-AsbestosNon-Asbestos1
21GasketNon-AsbestosNon-Asbestos2
20PlugSteelSteel1
19BoltCarbon SteelSCM4356
18BoltCarbon SteelSCM43512
17Lock NutSteelSteel1
16Adjusting ScrewSteelSteel1
15Top Spring PlateRolled SteelSS4001
14SpringAlloy SteelSWOSC1
13GasketCopperC1100P1
12Bottom Spring PlateRolled SteelSS4001
10U NutStainless SteelSUS1
9BellowsStainless SteelSUS316L1
8GuideStainless SteelSUS4032
7Bottom Valve SeatStainless SteelSUS420J21
6Top Valve SeatStainless SteelSUS420J21
5ValveStainless SteelSUS420J21

Note

This drawing may contain legally protected information such as confidential information. The production of prototypes and mass-produced products using this drawing, as well as the disclosure of content and information to third parties, is prohibited.