OB, GPR, CF, and GD series self-operated regulators for pressure and temperature control without external power.
Compare only the points that determine the choice: function or construction, applicable medium, operating range, body material, and connection or nominal size. Open the model page to confirm the full specification.
| Model | Key selection point | Medium | Operating range | Body material | Connection / size |
|---|---|---|---|---|---|
| CF-60 | Constant Flow Valve | 5-60°C | 1.0 MPa 5-60°C | — | JIS Rc screwed / Flangeless (wafer type); 25A-50A: JIS Rc screwed; 65A-100A: Flangeless (wafer type) |
| CF-90 | Constant Flow Valve for Cold and Hot Water | Cold and hot water | 1.0 MPa 5 - 90°C | — | JIS Rc screwed; Constant flow valve, 1.0 MPa, JIS Rc screwed |
| CP-2005 | Combination Valve (Temperature Regulator with PRV), Ductile Cast Iron, 2.0 MPa | Heating fluid: Steam, Heated fluid: Water, Oil, Liquid | 0.1 - 2.0 MPa 220°C | — | JIS Rc screwed, JIS 10K/20K flanged; Temperature Regulator with PRV |
| GD-20R | Primary Pressure Regulating Valve and Pressure Sustaining Valve | Cold and hot water, Oil, Air, Other non-dangerous fluids | 0.05-0.7 MPa 5-80°C (GD-20R) / 5-60°C (GD-20RC) | — | Electrodeposition or tar-based coating |
| GD-20RC | Primary Pressure Regulating Valve / Pressure Sustaining Valve | Cold and hot water | (A) 0.05-0.25 MPa, (B) 0.26-0.7 MPa 5 - 60 °C | Ductile cast iron (FCD450) with Nylon 11 coating | JIS 10K FF Flanged; Nylon 11 coated (inside and outside surfaces) |
| GD-21 | Differential Pressure Regulating Valve | Cold and hot water | 15A-80A: 0.05-0.7 MPa | 100A-150A: 0.05-0.5 MPa 5-80°C | Ductile cast iron | JIS 10K FF flanged; Differential pressure regulating valve, direct type |
| GD-47R | Primary Pressure Regulating Valve | Steam | 0.2-0.9 MPa 220°C or less | — | JIS 10K FF flanged; Primary pressure regulating valve, Steam, 0.2-0.9 MPa, External sensing |
| GD-4R | Primary Pressure Regulating Valve | Air, Other non-dangerous fluids | 2-200 kPa 5-80°C | — | JIS 10K FF flanged; 20-150A, JIS 10K FF |
| GPR-2000 | Primary Pressure Regulating Valve | Steam | External sensing type 220℃ | Ductile cast iron (FCD450) | JIS Rc screwed, JIS 20K RF flanged, JIS 10K FF flanged, NPT; Screwed: JIS Rc screwed connection; Flanged: JIS 20K RF / 10K FF flanged connection |
| MXV-1 | Mixing Valve | Cold and hot water | 1.0 MPa or less 38-65°C | — | Mixing valve, 25A-50A, JIS Rc screwed |
| OB-1 | Direct-Acting Temperature Regulator | Heating | 0.7 MPa 180°C | 0.7 MPa | JIS Rc screwed (union joint); Temperature regulator for standard ambient temperatures |
| OB-1G | Direct Acting Temperature Regulator | — | 0.7 MPa 180°C | 0.7 MPa | JIS Rc screwed (union joint); External pressure type bellows, 15-100°C range |
| OB-2 | OB-2G Direct Acting Temperature Regulator | Heating (Steam, Hot water) | Up to 0.7 MPa (depends on size) 180°C | Cast Iron | JIS 10K FF flanged; Standard bellows, temperature adjusting range 40-120°C |
| OB-2G | Temperature Regulator | Steam, Hot water | 0.7 MPa (15A-40A) 15-100°C | — | JIS 10K FF flanged; External pressure type bellows, 15A-125A |
| OB-2000 | Pilot Operated Temperature Regulator | Steam | 2.0 MPa 220°C | — | JIS Rc screwed, JIS 10K FF / 20K RF flanged; Pilot operated temperature regulator, 2.0 MPa, 220°C |
| OB-3 | Temperature Regulator Valve | Cooling / Heating | 0.7 MPa 180°C | 0.7 MPa | JIS Rc screwed (union joint); Standard temperature regulator valve, 40-120°C |
| OB-3G | Temperature Regulator Valve | — | 0.7 MPa 180°C | 0.7 MPa | JIS Rc screwed (union joint); External pressure type bellows, 15-100°C range |
| OB-30 | Temperature Regulator | — | 1.0 MPa (1.7 MPa for hot water/cooling) 185°C | Bronze | JIS Rc screwed / Union joint; For heating, JIS Rc screwed |
| OB-30U | — | — | 1.0 MPa (1.7 MPa for hot water/cooling) 185°C | Bronze | JIS Rc screwed / Union joint; For heating, JIS Rc screwed (union joint) |
| OB-31 | Temperature Regulator for Cooling | Cold water, Refrigerant | 1.7 MPa | Bronze | JIS Rc screwed; For cooling, JIS Rc screwed connection |
| OB-31U | Direct-Acting Temperature Regulator for Cooling | Cold water, Refrigerant | 1.7 MPa 185°C (Sensor max 100°C for cooling) | Bronze | JIS Rc screwed (union joint); For cooling, union joint, max pressure 1.7 MPa |
| OB-4 | OB-4G Direct Acting Temperature Regulator Valve | — | 0.7 MPa (15A-40A) / 0.5 MPa (50A-65A) / 0.4 MPa (80A-100A) / 0.2 MPa (125A-150A) 180°C | Cast iron | JIS 10K FF flanged; Standard bellows, 40-120°C adjusting range, 15A-150A |
| OB-4G | Temperature Regulator Valve (Cooling) | Cooling | 180°C | Cast iron | JIS 10K FF flanged; 15A-125A, JIS 10K FF flanged, For Cooling |
Yoshitake self-operated regulators maintain pressure or temperature without an external powered controller in the local catalogue. The product group includes pressure regulators and temperature regulators for heating, cooling, water, oil, and steam systems; choose by the controlled variable, sensing arrangement, medium, range, and available pressure differential.
This guide groups local Yoshitake catalogue pages for preliminary engineering review. The model-specific Yoshitake documentation, sizing calculation, materials confirmation, and applicable site requirements control the final order and installation decision.
Open a model page for specifications, connection options and technical documents.